Copper Alloy C97600-M01 vs C97600-M04

Copper Alloy · C97600 temper comparison

C97600-M01 and C97600-M04 are two conditions of the same copper alloy grade, C97600: M01 (as sand cast) versus M04 (as pressure die cast). The chemistry is identical, so every difference below comes from the condition. C97600-M04 is the stronger of the two: yield strength 175 MPa (25.4 ksi) against 165 MPa (23.9 ksi) for C97600-M01, about 6% more. In exchange, C97600-M01 is the more ductile: elongation 20% versus 18% for C97600-M04, and C97600-M04 is harder (85 HB vs 80 HB).

C97600-M01Choose it when the part is bent, formed or impact-loaded.

C97600-M04Choose it when strength drives the design.

C97600-M01 vs C97600-M04: properties

C97600-M01C97600-M04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

310 MPa45 ksi
325 MPa47.1 ksi

Yield Strength (0.2% offset)

165 MPa23.9 ksi
175 MPa25.4 ksi

Elongation at Break

20%
18%

Compressive Strength

330 MPa47.9 ksi
345 MPa50 ksi

Shear Strength

240 MPa34.8 ksi
245 MPa35.5 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
110 MPa16 ksi

Charpy V-Notch Impact (RT)

20 J14.8 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

80 HB
85 HB

Hardness, Rockwell B

42 HRB
46 HRB

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 52 GPa7.5 Msi · Bulk Modulus 125 GPa18.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,108°C2,026 °F · Liquidus Temperature 1,143°C2,089 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.5 % IACS · Electrical Resistivity 3.87×10⁻⁷ Ω·m15.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

15 / 100
10 / 100

Same in both: Machinability 70 / 100 · Machinability Rating (AISI 1212 = 100 %) 90% · Weldability 25 / 100 · Castability 70 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC97600

C97600-M01 vs C97600-M04 — frequently asked

Is C97600-M04 stronger than C97600-M01?

Yes. C97600-M04 has a typical yield strength of 175 MPa (25.4 ksi) against 165 MPa (23.9 ksi) for C97600-M01 — about 6% more. Tensile strength is 325 MPa (47.1 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, M01 or M04?

M01 is the default C97600 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C97600-M01 over C97600-M04?

Pick C97600-M01 when the part is bent, formed or impact-loaded. Pick C97600-M04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C97600-M01 and C97600-M04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.