FabDigitFabDigit

Copper Alloy C97600-M02 vs C97600-M07

Copper Alloy · C97600 temper comparison

C97600-M02 and C97600-M07 are two conditions of the same copper alloy grade, C97600: M02 (as centrifugally cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C97600-M07 is the stronger of the two: yield strength 195 MPa (28.3 ksi) against 180 MPa (26.1 ksi) for C97600-M02, about 8% more. In exchange, C97600-M02 is the more ductile: elongation 18% versus 15% for C97600-M07, and C97600-M07 is harder (90 HB vs 85 HB).

C97600-M02Choose it when the part is bent, formed or impact-loaded.

C97600-M07Choose it when strength drives the design.

C97600-M02 vs C97600-M07: properties

C97600-M02C97600-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

330 MPa47.9 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
195 MPa28.3 ksi

Elongation at Break

18%
15%

Compressive Strength

350 MPa50.8 ksi
365 MPa52.9 ksi

Shear Strength

250 MPa36.3 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
120 MPa17.4 ksi

Charpy V-Notch Impact (RT)

18 J13.3 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

85 HB
90 HB

Hardness, Rockwell B

46 HRB
50 HRB

Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 52 GPa7.5 Msi · Bulk Modulus 125 GPa18.1 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,108°C2,026 °F · Liquidus Temperature 1,143°C2,089 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 26 W/m·K15 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Max Service Temperature (continuous) 260°C500 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.5 % IACS · Electrical Resistivity 3.87×10⁻⁷ Ω·m15.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
72 / 100

Machinability Rating (AISI 1212 = 100 %)

90%
92%

Same in both: Weldability 25 / 100 · Formability (cold) 10 / 100 · Castability 70 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.5 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC97600

C97600-M02 vs C97600-M07 — frequently asked

Is C97600-M07 stronger than C97600-M02?

Yes. C97600-M07 has a typical yield strength of 195 MPa (28.3 ksi) against 180 MPa (26.1 ksi) for C97600-M02 — about 8% more. Tensile strength is 345 MPa (50 ksi) vs 330 MPa (47.9 ksi).

Which condition does FabDigit quote by default, M02 or M07?

M01 is the default C97600 condition in the FabDigit quote flow (neither M02 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C97600-M02 over C97600-M07?

Pick C97600-M02 when the part is bent, formed or impact-loaded. Pick C97600-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C97600-M02 and C97600-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.