FabDigitFabDigit

Copper Alloy C94300-M01 vs C94300-M07

Copper Alloy · C94300 temper comparison

C94300-M01 and C94300-M07 are two conditions of the same copper alloy grade, C94300: M01 (as sand cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C94300-M07 is the stronger of the two: yield strength 105 MPa (15.2 ksi) against 90 MPa (13.1 ksi) for C94300-M01, about 17% more; tensile strength follows at 205 MPa (29.7 ksi) vs 186 MPa (27 ksi). In exchange, C94300-M01 is the more ductile: elongation 15% versus 12% for C94300-M07, and C94300-M07 is harder (55 HB vs 48 HB).

C94300-M01Choose it when the part is bent, formed or impact-loaded.

C94300-M07Choose it when strength drives the design.

C94300-M01 vs C94300-M07: properties

C94300-M01C94300-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

70 GPa10.2 Msi
72 GPa10.4 Msi

Tensile Strength (Ultimate)

186 MPa27 ksi
205 MPa29.7 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
105 MPa15.2 ksi

Elongation at Break

15%
12%

Shear Strength

135 MPa19.6 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
55 MPa8 ksi

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

48 HB
55 HB

Hardness, Vickers

50 HV
57 HV

Same in both: Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 105 GPa15.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 9.29 g/cm³0.34 lb/in³ · Melting Point (Solidus) 762°C1,404 °F · Liquidus Temperature 954°C1,749 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 46.7 W/m·K27 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.5 µm/m·K10.3 µin/in·°F · Max Service Temperature (continuous) 230°C446 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

56 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

88 / 100
90 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 130% · Weldability 8 / 100 · Formability (cold) 5 / 100 · Castability 85 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 45 MJ/kg19,347 BTU/lb · Embodied Carbon (primary production) 3 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC94300

C94300-M01 vs C94300-M07 — frequently asked

Is C94300-M07 stronger than C94300-M01?

Yes. C94300-M07 has a typical yield strength of 105 MPa (15.2 ksi) against 90 MPa (13.1 ksi) for C94300-M01 — about 17% more. Tensile strength is 205 MPa (29.7 ksi) vs 186 MPa (27 ksi).

Which condition does FabDigit quote by default, M01 or M07?

M07 is the default C94300 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C94300-M01 over C94300-M07?

Pick C94300-M01 when the part is bent, formed or impact-loaded. Pick C94300-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C94300-M01 and C94300-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.