C91000-M01 and C91000-M02 are two conditions of the same copper alloy grade, C91000: M01 (as sand cast) versus M02 (as centrifugally cast). The chemistry is identical, so every difference below comes from the condition. C91000-M02 is the stronger of the two: yield strength 165 MPa (23.9 ksi) against 150 MPa (21.8 ksi) for C91000-M01, about 10% more; tensile strength follows at 250 MPa (36.3 ksi) vs 225 MPa (32.6 ksi). C91000-M02 is the more ductile: elongation 2% versus 1.5% for C91000-M01.

C91000-M02Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C91000-M01 vs C91000-M02: properties

C91000-M01C91000-M02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

103 GPa14.9 Msi
105 GPa15.2 Msi

Tensile Strength (Ultimate)

225 MPa32.6 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
165 MPa23.9 ksi

Elongation at Break

1.5%
2%

Reduction in Area

2%
3%

Compressive Strength

550 MPa79.8 ksi
580 MPa84.1 ksi

Shear Strength

170 MPa24.7 ksi
185 MPa26.8 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
100 MPa14.5 ksi

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

135 HB
140 HB

Hardness, Rockwell B

75 HRB
77 HRB

Hardness, Vickers

140 HV
146 HV

Same in both: Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.8 g/cm³0.32 lb/in³ · Melting Point (Solidus) 830°C1,526 °F · Liquidus Temperature 1,000°C1,832 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 47 W/m·K27.2 BTU/hr·ft·°F · Specific Heat Capacity 376 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
66 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 15 / 100 · Formability (cold) 5 / 100 · Castability 70 / 100 · Brazeability / Solderability 60 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC91000

C91000-M01 vs C91000-M02 — frequently asked

Is C91000-M02 stronger than C91000-M01?

Yes. C91000-M02 has a typical yield strength of 165 MPa (23.9 ksi) against 150 MPa (21.8 ksi) for C91000-M01 — about 10% more. Tensile strength is 250 MPa (36.3 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, M01 or M02?

M01 is the default C91000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C91000-M01 over C91000-M02?

Pick C91000-M02 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C91000-M01 and C91000-M02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.