FabDigitFabDigit

Copper Alloy C84500-M06 vs C84500-M07

Copper Alloy · C84500 temper comparison

C84500-M06 and C84500-M07 are two conditions of the same copper alloy grade, C84500: M06 (as investment cast) versus M07 (as continuous cast). The chemistry is identical, so every difference below comes from the condition. C84500-M07 is the stronger of the two: yield strength 124 MPa (18 ksi) against 103 MPa (14.9 ksi) for C84500-M06, about 20% more; tensile strength follows at 262 MPa (38 ksi) vs 241 MPa (35 ksi). In exchange, C84500-M06 is the more ductile: elongation 25% versus 22% for C84500-M07, and C84500-M07 is harder (60 HB vs 55 HB).

C84500-M06Choose it when the part is bent, formed or impact-loaded.

C84500-M07Choose it when strength drives the design.

C84500-M06 vs C84500-M07: properties

C84500-M06C84500-M07

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

241 MPa35 ksi
262 MPa38 ksi

Yield Strength (0.2% offset)

103 MPa14.9 ksi
124 MPa18 ksi

Elongation at Break

25%
22%

Reduction in Area

19%
18%

Shear Strength

172 MPa24.9 ksi
186 MPa27 ksi

Fatigue Strength (Endurance Limit)

76 MPa11 ksi
83 MPa12 ksi

Hardness, Brinell

55 HB
60 HB

Hardness, Vickers

58 HV
63 HV

Same in both: Elastic (Young's) Modulus 90 GPa13.1 Msi · Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 95 GPa13.8 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 14 J10.3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.58 g/cm³0.31 lb/in³ · Melting Point (Solidus) 843°C1,549 °F · Liquidus Temperature 1,004°C1,839 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 72 W/m·K41.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 16 % IACS · Electrical Resistivity 1.08×10⁻⁷ Ω·m4.25 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 85 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 20 / 100 · Formability (cold) 15 / 100 · Castability 80 / 100 · Brazeability / Solderability 85 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC84500

C84500-M06 vs C84500-M07 — frequently asked

Is C84500-M07 stronger than C84500-M06?

Yes. C84500-M07 has a typical yield strength of 124 MPa (18 ksi) against 103 MPa (14.9 ksi) for C84500-M06 — about 20% more. Tensile strength is 262 MPa (38 ksi) vs 241 MPa (35 ksi).

Which condition does FabDigit quote by default, M06 or M07?

M01 is the default C84500 condition in the FabDigit quote flow (neither M06 nor M07). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C84500-M06 over C84500-M07?

Pick C84500-M06 when the part is bent, formed or impact-loaded. Pick C84500-M07 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C84500-M06 and C84500-M07 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.