FabDigitFabDigit

Copper Alloy C84500-M05 vs C84500-M06

Copper Alloy · C84500 temper comparison

C84500-M05 and C84500-M06 are two conditions of the same copper alloy grade, C84500: M05 (as plaster cast) versus M06 (as investment cast). The chemistry is identical, so every difference below comes from the condition. C84500-M05 is the stronger of the two: yield strength 117 MPa (17 ksi) against 103 MPa (14.9 ksi) for C84500-M06, about 14% more; tensile strength follows at 255 MPa (37 ksi) vs 241 MPa (35 ksi). In exchange, C84500-M06 is the more ductile: elongation 25% versus 20% for C84500-M05, and C84500-M05 is harder (60 HB vs 55 HB).

C84500-M05Choose it when strength drives the design.

C84500-M06Choose it when the part is bent, formed or impact-loaded.

C84500-M05 vs C84500-M06: properties

C84500-M05C84500-M06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
241 MPa35 ksi

Yield Strength (0.2% offset)

117 MPa17 ksi
103 MPa14.9 ksi

Elongation at Break

20%
25%

Reduction in Area

17%
19%

Shear Strength

179 MPa26 ksi
172 MPa24.9 ksi

Fatigue Strength (Endurance Limit)

83 MPa12 ksi
76 MPa11 ksi

Charpy V-Notch Impact (RT)

13 J9.6 ft·lbf
14 J10.3 ft·lbf

Hardness, Brinell

60 HB
55 HB

Hardness, Vickers

63 HV
58 HV

Same in both: Elastic (Young's) Modulus 90 GPa13.1 Msi · Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 95 GPa13.8 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.58 g/cm³0.31 lb/in³ · Melting Point (Solidus) 843°C1,549 °F · Liquidus Temperature 1,004°C1,839 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 72 W/m·K41.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 16 % IACS · Electrical Resistivity 1.08×10⁻⁷ Ω·m4.25 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 85 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 20 / 100 · Formability (cold) 15 / 100 · Castability 80 / 100 · Brazeability / Solderability 85 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC84500

C84500-M05 vs C84500-M06 — frequently asked

Is C84500-M05 stronger than C84500-M06?

Yes. C84500-M05 has a typical yield strength of 117 MPa (17 ksi) against 103 MPa (14.9 ksi) for C84500-M06 — about 14% more. Tensile strength is 255 MPa (37 ksi) vs 241 MPa (35 ksi).

Which condition does FabDigit quote by default, M05 or M06?

M01 is the default C84500 condition in the FabDigit quote flow (neither M05 nor M06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C84500-M05 over C84500-M06?

Pick C84500-M05 when strength drives the design. Pick C84500-M06 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C84500-M05 and C84500-M06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.