FabDigitFabDigit

Copper Alloy C84500-M02 vs C84500-M06

Copper Alloy · C84500 temper comparison

C84500-M02 and C84500-M06 are two conditions of the same copper alloy grade, C84500: M02 (as centrifugally cast) versus M06 (as investment cast). The chemistry is identical, so every difference below comes from the condition. C84500-M02 is the stronger of the two: yield strength 110 MPa (16 ksi) against 103 MPa (14.9 ksi) for C84500-M06, about 7% more. C84500-M02 is harder — 58 HB against 55 HB for C84500-M06 — which matters for wear surfaces and threads.

C84500-M02Choose it when strength drives the design, or when surface hardness matters.

C84500-M02 vs C84500-M06: properties

C84500-M02C84500-M06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

248 MPa36 ksi
241 MPa35 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
103 MPa14.9 ksi

Reduction in Area

20%
19%

Shear Strength

176 MPa25.5 ksi
172 MPa24.9 ksi

Fatigue Strength (Endurance Limit)

79 MPa11.5 ksi
76 MPa11 ksi

Hardness, Brinell

58 HB
55 HB

Hardness, Vickers

61 HV
58 HV

Same in both: Elastic (Young's) Modulus 90 GPa13.1 Msi · Shear Modulus 34 GPa4.9 Msi · Bulk Modulus 95 GPa13.8 Msi · Poisson's Ratio 0.34 · Elongation at Break 25% · Charpy V-Notch Impact (RT) 14 J10.3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.58 g/cm³0.31 lb/in³ · Melting Point (Solidus) 843°C1,549 °F · Liquidus Temperature 1,004°C1,839 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 72 W/m·K41.6 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.3 µm/m·K11.3 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 16 % IACS · Electrical Resistivity 1.08×10⁻⁷ Ω·m4.25 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 85 / 100 · Machinability Rating (AISI 1212 = 100 %) 80% · Weldability 20 / 100 · Formability (cold) 15 / 100 · Castability 80 / 100 · Brazeability / Solderability 85 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 52 MJ/kg22,356 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC84500

C84500-M02 vs C84500-M06 — frequently asked

Is C84500-M02 stronger than C84500-M06?

Yes. C84500-M02 has a typical yield strength of 110 MPa (16 ksi) against 103 MPa (14.9 ksi) for C84500-M06 — about 7% more. Tensile strength is 248 MPa (36 ksi) vs 241 MPa (35 ksi).

Which condition does FabDigit quote by default, M02 or M06?

M01 is the default C84500 condition in the FabDigit quote flow (neither M02 nor M06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C84500-M02 over C84500-M06?

Pick C84500-M02 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C84500-M02 and C84500-M06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.