FabDigitFabDigit

Copper Alloy C79600-M30 vs C79600-O61

Copper Alloy · C79600 temper comparison

C79600-M30 and C79600-O61 are two conditions of the same copper alloy grade, C79600: M30 (as hot extruded) versus O61 (annealed). The chemistry is identical, so every difference below comes from the condition. C79600-M30 is the stronger of the two: yield strength 210 MPa (30.5 ksi) against 165 MPa (23.9 ksi) for C79600-O61, about 27% more; tensile strength follows at 450 MPa (65.3 ksi) vs 400 MPa (58 ksi). In exchange, C79600-O61 is the more ductile: elongation 32% versus 25% for C79600-M30, and C79600-M30 is harder (125 HB vs 105 HB).

C79600-M30Choose it when strength drives the design.

C79600-O61Choose it when the part is bent, formed or impact-loaded.

C79600-M30 vs C79600-O61: properties

C79600-M30C79600-O61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

450 MPa65.3 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

210 MPa30.5 ksi
165 MPa23.9 ksi

Elongation at Break

25%
32%

Shear Strength

300 MPa43.5 ksi
270 MPa39.2 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
150 MPa21.8 ksi

Hardness, Brinell

125 HB
105 HB

Hardness, Rockwell B

70 HRB
58 HRB

Hardness, Vickers

130 HV
110 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.52 g/cm³0.31 lb/in³ · Melting Point (Solidus) 875°C1,607 °F · Liquidus Temperature 925°C1,697 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

33 W/m·K19.1 BTU/hr·ft·°F
34 W/m·K19.6 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18 µm/m·K10 µin/in·°F · Latent Heat of Fusion 175 J/g75.2 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

8.5 % IACS
9 % IACS

Electrical Resistivity

2.03×10⁻⁷ Ω·m7.99 µΩ·in
1.92×10⁻⁷ Ω·m7.56 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
56 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

67 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

65%
60%

Formability (cold)

42 / 100
50 / 100

Same in both: Weldability 20 / 100 · Brazeability / Solderability 70 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC79600

C79600-M30 vs C79600-O61 — frequently asked

Is C79600-M30 stronger than C79600-O61?

Yes. C79600-M30 has a typical yield strength of 210 MPa (30.5 ksi) against 165 MPa (23.9 ksi) for C79600-O61 — about 27% more. Tensile strength is 450 MPa (65.3 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, M30 or O61?

H02 is the default C79600 condition in the FabDigit quote flow (neither M30 nor O61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C79600-M30 or C79600-O61?

C79600-M30, by a small margin. Both rate good for machinability — 67/100 against 62/100 for C79600-O61.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C79600-M30 and C79600-O61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.