FabDigitFabDigit

Copper Alloy C77400-H06 vs C77400-H10

Copper Alloy · C77400 temper comparison

C77400-H06 and C77400-H10 are two conditions of the same copper alloy grade, C77400: H06 (extra hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C77400-H10 is the stronger of the two: yield strength 700 MPa (102 ksi) against 620 MPa (89.9 ksi) for C77400-H06, about 13% more; tensile strength follows at 760 MPa (110 ksi) vs 690 MPa (100 ksi). In exchange, C77400-H06 is the more ductile: elongation 2% versus 1.5% for C77400-H10, and C77400-H10 is harder (223 HB vs 195 HB). C77400-H06 runs hotter in service (175°C vs 150°C continuous).

C77400-H06Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C77400-H10Choose it when strength drives the design.

C77400-H06 vs C77400-H10: properties

C77400-H06C77400-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

125 GPa18.1 Msi
128 GPa18.6 Msi

Tensile Strength (Ultimate)

690 MPa100 ksi
760 MPa110 ksi

Yield Strength (0.2% offset)

620 MPa89.9 ksi
700 MPa102 ksi

Elongation at Break

2%
1.5%

Shear Strength

405 MPa58.7 ksi
445 MPa64.5 ksi

Fatigue Strength (Endurance Limit)

245 MPa35.5 ksi
255 MPa37 ksi

Hardness, Brinell

195 HB
223 HB

Hardness, Rockwell B

91 HRB
95 HRB

Hardness, Vickers

205 HV
235 HV

Same in both: Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 122 GPa17.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.7 g/cm³0.31 lb/in³ · Melting Point (Solidus) 960°C1,760 °F · Liquidus Temperature 1,010°C1,850 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

11 % IACS
10.5 % IACS

Electrical Resistivity

1.57×10⁻⁷ Ω·m6.18 µΩ·in
1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

45 / 100
40 / 100

Formability (cold)

40 / 100
25 / 100

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 25% · Brazeability / Solderability 85 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC77400

C77400-H06 vs C77400-H10 — frequently asked

Is C77400-H10 stronger than C77400-H06?

Yes. C77400-H10 has a typical yield strength of 700 MPa (102 ksi) against 620 MPa (89.9 ksi) for C77400-H06 — about 13% more. Tensile strength is 760 MPa (110 ksi) vs 690 MPa (100 ksi).

Which condition does FabDigit quote by default, H06 or H10?

H02 is the default C77400 condition in the FabDigit quote flow (neither H06 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C77400-H06 or C77400-H10?

C77400-H06. Its weldability rates fair (45/100) against fair (40/100) for C77400-H10.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C77400-H06 and C77400-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.