FabDigitFabDigit

Copper Alloy C75400-H02 vs C75400-H06

Copper Alloy · C75400 temper comparison

C75400-H02 and C75400-H06 are two conditions of the same copper alloy grade, C75400: H02 (half hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C75400-H06 is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 425 MPa (61.6 ksi) for C75400-H02, about 34% more; tensile strength follows at 640 MPa (92.8 ksi) vs 515 MPa (74.7 ksi). In exchange, C75400-H02 is the more ductile: elongation 12% versus 3% for C75400-H06, and C75400-H06 is harder (185 HB vs 140 HB). C75400-H02 runs hotter in service (200°C vs 165°C continuous).

C75400-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C75400-H06Choose it when strength drives the design.

C75400-H02 vs C75400-H06: properties

C75400-H02C75400-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

515 MPa74.7 ksi
640 MPa92.8 ksi

Yield Strength (0.2% offset)

425 MPa61.6 ksi
570 MPa82.7 ksi

Elongation at Break

12%
3%

Shear Strength

330 MPa47.9 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

190 MPa27.6 ksi
215 MPa31.2 ksi

Hardness, Brinell

140 HB
185 HB

Hardness, Rockwell B

75 HRB
87 HRB

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 122 GPa17.7 Msi · Poisson's Ratio 0.33 · Hardness, Vickers 150 HV

Physical

Density and transition temperatures.

Same in both: Density 8.72 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,021°C1,870 °F · Liquidus Temperature 1,054°C1,929 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
165°C329 °F

Same in both: Thermal Conductivity 37 W/m·K21.4 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 6.5 % IACS · Electrical Resistivity 2.65×10⁻⁷ Ω·m10.4 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 66 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

20%
22%

Formability (cold)

55 / 100
28 / 100

Same in both: Machinability 30 / 100 · Weldability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 78 MJ/kg33,534 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC75400

C75400-H02 vs C75400-H06 — frequently asked

Is C75400-H06 stronger than C75400-H02?

Yes. C75400-H06 has a typical yield strength of 570 MPa (82.7 ksi) against 425 MPa (61.6 ksi) for C75400-H02 — about 34% more. Tensile strength is 640 MPa (92.8 ksi) vs 515 MPa (74.7 ksi).

Which condition does FabDigit quote by default, H02 or H06?

H02 is the default C75400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C75400-H02 over C75400-H06?

Pick C75400-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C75400-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C75400-H02 and C75400-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.