FabDigitFabDigit

Copper Alloy C74000-H01 vs C74000-H02

Copper Alloy · C74000 temper comparison

C74000-H01 and C74000-H02 are two conditions of the same copper alloy grade, C74000: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C74000-H02 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 275 MPa (39.9 ksi) for C74000-H01, about 38% more; tensile strength follows at 470 MPa (68.2 ksi) vs 415 MPa (60.2 ksi). In exchange, C74000-H01 is the more ductile: elongation 25% versus 12% for C74000-H02, and C74000-H02 is harder (145 HB vs 120 HB). C74000-H01 runs hotter in service (220°C vs 200°C continuous).

C74000-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C74000-H02Choose it when strength drives the design.

C74000-H01 vs C74000-H02: properties

C74000-H01C74000-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

415 MPa60.2 ksi
470 MPa68.2 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
380 MPa55.1 ksi

Elongation at Break

25%
12%

Shear Strength

270 MPa39.2 ksi
300 MPa43.5 ksi

Fatigue Strength (Endurance Limit)

180 MPa26.1 ksi
200 MPa29 ksi

Hardness, Brinell

120 HB
145 HB

Hardness, Rockwell B

60 HRB
75 HRB

Hardness, Vickers

128 HV
155 HV

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,010°C1,850 °F · Liquidus Temperature 1,040°C1,904 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

220°C428 °F
200°C392 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

72 / 100
60 / 100

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 55 / 100 · Brazeability / Solderability 85 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC74000

C74000-H01 vs C74000-H02 — frequently asked

Is C74000-H02 stronger than C74000-H01?

Yes. C74000-H02 has a typical yield strength of 380 MPa (55.1 ksi) against 275 MPa (39.9 ksi) for C74000-H01 — about 38% more. Tensile strength is 470 MPa (68.2 ksi) vs 415 MPa (60.2 ksi).

Which condition does FabDigit quote by default, H01 or H02?

H02 is the default C74000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C74000-H01 over C74000-H02?

Pick C74000-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C74000-H02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C74000-H01 and C74000-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.