FabDigitFabDigit

Copper Alloy C74000-H02 vs C74000-H06

Copper Alloy · C74000 temper comparison

C74000-H02 and C74000-H06 are two conditions of the same copper alloy grade, C74000: H02 (half hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C74000-H06 is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 380 MPa (55.1 ksi) for C74000-H02, about 45% more; tensile strength follows at 620 MPa (89.9 ksi) vs 470 MPa (68.2 ksi). In exchange, C74000-H02 is the more ductile: elongation 12% versus 2.5% for C74000-H06, and C74000-H06 is harder (195 HB vs 145 HB). C74000-H02 runs hotter in service (200°C vs 175°C continuous).

C74000-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C74000-H06Choose it when strength drives the design.

C74000-H02 vs C74000-H06: properties

C74000-H02C74000-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
550 MPa79.8 ksi

Elongation at Break

12%
2.5%

Shear Strength

300 MPa43.5 ksi
355 MPa51.5 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
240 MPa34.8 ksi

Hardness, Brinell

145 HB
195 HB

Hardness, Rockwell B

75 HRB
90 HRB

Hardness, Vickers

155 HV
210 HV

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,010°C1,850 °F · Liquidus Temperature 1,040°C1,904 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 9 % IACS · Electrical Resistivity 1.9×10⁻⁷ Ω·m7.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

20%
25%

Formability (cold)

60 / 100
28 / 100

Same in both: Machinability 30 / 100 · Weldability 55 / 100 · Brazeability / Solderability 85 / 100 · Polishability 88 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 75 MJ/kg32,244 BTU/lb · Embodied Carbon (primary production) 5.2 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC74000

C74000-H02 vs C74000-H06 — frequently asked

Is C74000-H06 stronger than C74000-H02?

Yes. C74000-H06 has a typical yield strength of 550 MPa (79.8 ksi) against 380 MPa (55.1 ksi) for C74000-H02 — about 45% more. Tensile strength is 620 MPa (89.9 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, H02 or H06?

H02 is the default C74000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C74000-H02 over C74000-H06?

Pick C74000-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C74000-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C74000-H02 and C74000-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.