C71700-H04 and C71700-H80 are two conditions of the same copper alloy grade, C71700: H04 (full hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C71700-H04 is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 515 MPa (74.7 ksi) for C71700-H80, about 7% more; tensile strength follows at 620 MPa (89.9 ksi) vs 585 MPa (84.8 ksi). In exchange, C71700-H80 is the more ductile: elongation 10% versus 8% for C71700-H04, and C71700-H04 is harder (190 HB vs 175 HB).

C71700-H04Choose it when strength drives the design.

C71700-H80Choose it when the part is bent, formed or impact-loaded.

C71700-H04 vs C71700-H80: properties

C71700-H04C71700-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

550 MPa79.8 ksi
515 MPa74.7 ksi

Elongation at Break

8%
10%

Reduction in Area

30%
35%

Shear Strength

400 MPa58 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

210 MPa30.5 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

190 HB
175 HB

Hardness, Rockwell B

92 HRB
88 HRB

Hardness, Vickers

200 HV
185 HV

Same in both: Elastic (Young's) Modulus 152 GPa22 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,170°C2,138 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.5 % IACS · Electrical Resistivity 3.83×10⁻⁷ Ω·m15.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

84 / 100
85 / 100

Formability (cold)

25 / 100
35 / 100

Same in both: Machinability 30 / 100 · Machinability Rating (AISI 1212 = 100 %) 30% · Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 105 MJ/kg45,142 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71700

C71700-H04 vs C71700-H80 — frequently asked

Is C71700-H04 stronger than C71700-H80?

Yes. C71700-H04 has a typical yield strength of 550 MPa (79.8 ksi) against 515 MPa (74.7 ksi) for C71700-H80 — about 7% more. Tensile strength is 620 MPa (89.9 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, H04 or H80?

O61 is the default C71700 condition in the FabDigit quote flow (neither H04 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C71700-H04 over C71700-H80?

Pick C71700-H04 when strength drives the design. Pick C71700-H80 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71700-H04 and C71700-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.