FabDigitFabDigit

Copper Alloy C71700-H01 vs C71700-H04

Copper Alloy · C71700 temper comparison

C71700-H01 and C71700-H04 are two conditions of the same copper alloy grade, C71700: H01 (quarter hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C71700-H04 is the stronger of the two: yield strength 550 MPa (79.8 ksi) against 310 MPa (45 ksi) for C71700-H01, about 77% more; tensile strength follows at 620 MPa (89.9 ksi) vs 470 MPa (68.2 ksi). In exchange, C71700-H01 is the more ductile: elongation 22% versus 8% for C71700-H04, and C71700-H04 is harder (190 HB vs 125 HB). C71700-H01 runs hotter in service (350°C vs 300°C continuous).

C71700-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C71700-H04Choose it when strength drives the design.

C71700-H01 vs C71700-H04: properties

C71700-H01C71700-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
550 MPa79.8 ksi

Elongation at Break

22%
8%

Reduction in Area

50%
30%

Shear Strength

320 MPa46.4 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
210 MPa30.5 ksi

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
30 J22.1 ft·lbf

Hardness, Brinell

125 HB
190 HB

Hardness, Rockwell B

70 HRB
92 HRB

Hardness, Vickers

135 HV
200 HV

Same in both: Elastic (Young's) Modulus 152 GPa22 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,170°C2,138 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
300°C572 °F

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4.6 % IACS
4.5 % IACS

Electrical Resistivity

3.75×10⁻⁷ Ω·m14.8 µΩ·in
3.83×10⁻⁷ Ω·m15.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

88 / 100
84 / 100

Formability (cold)

60 / 100
25 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 105 MJ/kg45,142 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71700

C71700-H01 vs C71700-H04 — frequently asked

Is C71700-H04 stronger than C71700-H01?

Yes. C71700-H04 has a typical yield strength of 550 MPa (79.8 ksi) against 310 MPa (45 ksi) for C71700-H01 — about 77% more. Tensile strength is 620 MPa (89.9 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, H01 or H04?

O61 is the default C71700 condition in the FabDigit quote flow (neither H01 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C71700-H01 or C71700-H04?

C71700-H04, by a small margin. Both rate poor for machinability — 30/100 against 24/100 for C71700-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71700-H01 and C71700-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.