FabDigitFabDigit

Copper Alloy C71700-H02 vs C71700-H80

Copper Alloy · C71700 temper comparison

C71700-H02 and C71700-H80 are two conditions of the same copper alloy grade, C71700: H02 (half hard) versus H80 (hard drawn). The chemistry is identical, so every difference below comes from the condition. C71700-H80 is the stronger of the two: yield strength 515 MPa (74.7 ksi) against 420 MPa (60.9 ksi) for C71700-H02, about 23% more; tensile strength follows at 585 MPa (84.8 ksi) vs 540 MPa (78.3 ksi). In exchange, C71700-H02 is the more ductile: elongation 14% versus 10% for C71700-H80, and C71700-H80 is harder (175 HB vs 155 HB).

C71700-H02Choose it when the part is bent, formed or impact-loaded.

C71700-H80Choose it when strength drives the design.

C71700-H02 vs C71700-H80: properties

C71700-H02C71700-H80

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

540 MPa78.3 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

420 MPa60.9 ksi
515 MPa74.7 ksi

Elongation at Break

14%
10%

Reduction in Area

42%
35%

Shear Strength

355 MPa51.5 ksi
380 MPa55.1 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
200 MPa29 ksi

Charpy V-Notch Impact (RT)

55 J40.6 ft·lbf
40 J29.5 ft·lbf

Hardness, Brinell

155 HB
175 HB

Hardness, Rockwell B

82 HRB
88 HRB

Hardness, Vickers

165 HV
185 HV

Same in both: Elastic (Young's) Modulus 152 GPa22 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,170°C2,138 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

325°C617 °F
300°C572 °F

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4.6 % IACS
4.5 % IACS

Electrical Resistivity

3.79×10⁻⁷ Ω·m14.9 µΩ·in
3.83×10⁻⁷ Ω·m15.1 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
30%

Weldability

86 / 100
85 / 100

Formability (cold)

45 / 100
35 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 105 MJ/kg45,142 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71700

C71700-H02 vs C71700-H80 — frequently asked

Is C71700-H80 stronger than C71700-H02?

Yes. C71700-H80 has a typical yield strength of 515 MPa (74.7 ksi) against 420 MPa (60.9 ksi) for C71700-H02 — about 23% more. Tensile strength is 585 MPa (84.8 ksi) vs 540 MPa (78.3 ksi).

Which condition does FabDigit quote by default, H02 or H80?

O61 is the default C71700 condition in the FabDigit quote flow (neither H02 nor H80). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C71700-H02 over C71700-H80?

Pick C71700-H02 when the part is bent, formed or impact-loaded. Pick C71700-H80 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71700-H02 and C71700-H80 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.