C71700-H01 and C71700-H02 are two conditions of the same copper alloy grade, C71700: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C71700-H02 is the stronger of the two: yield strength 420 MPa (60.9 ksi) against 310 MPa (45 ksi) for C71700-H01, about 35% more; tensile strength follows at 540 MPa (78.3 ksi) vs 470 MPa (68.2 ksi). In exchange, C71700-H01 is the more ductile: elongation 22% versus 14% for C71700-H02, and C71700-H02 is harder (155 HB vs 125 HB).

C71700-H01Choose it when the part is bent, formed or impact-loaded.

C71700-H02Choose it when strength drives the design.

C71700-H01 vs C71700-H02: properties

C71700-H01C71700-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
540 MPa78.3 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
420 MPa60.9 ksi

Elongation at Break

22%
14%

Reduction in Area

50%
42%

Shear Strength

320 MPa46.4 ksi
355 MPa51.5 ksi

Fatigue Strength (Endurance Limit)

165 MPa23.9 ksi
185 MPa26.8 ksi

Charpy V-Notch Impact (RT)

75 J55.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

125 HB
155 HB

Hardness, Rockwell B

70 HRB
82 HRB

Hardness, Vickers

135 HV
165 HV

Same in both: Elastic (Young's) Modulus 152 GPa22 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,170°C2,138 °F · Liquidus Temperature 1,240°C2,264 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

350°C662 °F
325°C617 °F

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 220 J/g94.6 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

4.6 % IACS
4.6 % IACS

Electrical Resistivity

3.75×10⁻⁷ Ω·m14.8 µΩ·in
3.79×10⁻⁷ Ω·m14.9 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

24 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
28%

Weldability

88 / 100
86 / 100

Formability (cold)

60 / 100
45 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 105 MJ/kg45,142 BTU/lb · Embodied Carbon (primary production) 7.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71700

C71700-H01 vs C71700-H02 — frequently asked

Is C71700-H02 stronger than C71700-H01?

Yes. C71700-H02 has a typical yield strength of 420 MPa (60.9 ksi) against 310 MPa (45 ksi) for C71700-H01 — about 35% more. Tensile strength is 540 MPa (78.3 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, H01 or H02?

O61 is the default C71700 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C71700-H01 over C71700-H02?

Pick C71700-H01 when the part is bent, formed or impact-loaded. Pick C71700-H02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71700-H01 and C71700-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.