FabDigitFabDigit

Copper Alloy C71500-H01 vs C71500-H02

Copper Alloy · C71500 temper comparison

C71500-H01 and C71500-H02 are two conditions of the same copper alloy grade, C71500: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C71500-H02 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 275 MPa (39.9 ksi) for C71500-H01, about 38% more; tensile strength follows at 450 MPa (65.3 ksi) vs 415 MPa (60.2 ksi). In exchange, C71500-H01 is the more ductile: elongation 25% versus 15% for C71500-H02, and C71500-H02 is harder (130 HB vs 110 HB).

C71500-H01Choose it when the part is bent, formed or impact-loaded.

C71500-H02Choose it when strength drives the design.

C71500-H01 vs C71500-H02: properties

C71500-H01C71500-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

415 MPa60.2 ksi
450 MPa65.3 ksi

Yield Strength (0.2% offset)

275 MPa39.9 ksi
380 MPa55.1 ksi

Elongation at Break

25%
15%

Reduction in Area

45%
35%

Shear Strength

290 MPa42.1 ksi
305 MPa44.2 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
170 MPa24.7 ksi

Charpy V-Notch Impact (RT)

90 J66.4 ft·lbf
65 J47.9 ft·lbf

Hardness, Brinell

110 HB
130 HB

Hardness, Rockwell B

62 HRB
72 HRB

Hardness, Vickers

115 HV
140 HV

Same in both: Elastic (Young's) Modulus 152 GPa22 Msi · Shear Modulus 57 GPa8.3 Msi · Bulk Modulus 158 GPa22.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,171°C2,140 °F · Liquidus Temperature 1,238°C2,260 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 29 W/m·K16.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 230 J/g98.9 BTU/lb · Max Service Temperature (continuous) 250°C482 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 4.6 % IACS · Electrical Resistivity 3.75×10⁻⁷ Ω·m14.8 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

81 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

22%
25%

Weldability

80 / 100
78 / 100

Formability (cold)

65 / 100
50 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 110 MJ/kg47,292 BTU/lb · Embodied Carbon (primary production) 7 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC71500

C71500-H01 vs C71500-H02 — frequently asked

Is C71500-H02 stronger than C71500-H01?

Yes. C71500-H02 has a typical yield strength of 380 MPa (55.1 ksi) against 275 MPa (39.9 ksi) for C71500-H01 — about 38% more. Tensile strength is 450 MPa (65.3 ksi) vs 415 MPa (60.2 ksi).

Which condition does FabDigit quote by default, H01 or H02?

O61 is the default C71500 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C71500-H01 or C71500-H02?

C71500-H02, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for C71500-H01.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C71500-H01 and C71500-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.