FabDigitFabDigit

Copper Alloy C70500-H02 vs C70500-H04

Copper Alloy · C70500 temper comparison

C70500-H02 and C70500-H04 are two conditions of the same copper alloy grade, C70500: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C70500-H04 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 280 MPa (40.6 ksi) for C70500-H02, about 32% more; tensile strength follows at 415 MPa (60.2 ksi) vs 350 MPa (50.8 ksi). In exchange, C70500-H02 is the more ductile: elongation 14% versus 6% for C70500-H04, and C70500-H04 is harder (110 HB vs 92 HB). C70500-H02 runs hotter in service (225°C vs 200°C continuous).

C70500-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C70500-H04Choose it when strength drives the design.

C70500-H02 vs C70500-H04: properties

C70500-H02C70500-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

350 MPa50.8 ksi
415 MPa60.2 ksi

Yield Strength (0.2% offset)

280 MPa40.6 ksi
370 MPa53.7 ksi

Elongation at Break

14%
6%

Reduction in Area

45%
35%

Shear Strength

220 MPa31.9 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
150 MPa21.8 ksi

Hardness, Brinell

92 HB
110 HB

Hardness, Vickers

96 HV
115 HV

Same in both: Elastic (Young's) Modulus 124 GPa18 Msi · Shear Modulus 46 GPa6.7 Msi · Bulk Modulus 132 GPa19.1 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,090°C1,994 °F · Liquidus Temperature 1,105°C2,021 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

225°C437 °F
200°C392 °F

Same in both: Thermal Conductivity 88 W/m·K50.8 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.1 µm/m·K9.5 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

7.1×10⁻⁸ Ω·m2.8 µΩ·in
7.2×10⁻⁸ Ω·m2.83 µΩ·in

Same in both: Electrical Conductivity 24 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

24%
25%

Weldability

78 / 100
75 / 100

Formability (cold)

50 / 100
30 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70500

C70500-H02 vs C70500-H04 — frequently asked

Is C70500-H04 stronger than C70500-H02?

Yes. C70500-H04 has a typical yield strength of 370 MPa (53.7 ksi) against 280 MPa (40.6 ksi) for C70500-H02 — about 32% more. Tensile strength is 415 MPa (60.2 ksi) vs 350 MPa (50.8 ksi).

Which condition does FabDigit quote by default, H02 or H04?

O61 is the default C70500 condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C70500-H02 over C70500-H04?

Pick C70500-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C70500-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70500-H02 and C70500-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.