FabDigitFabDigit

Copper Alloy C70260-TM00 vs C70260-TM04

Copper Alloy · C70260 temper comparison

C70260-TM00 and C70260-TM04 are two conditions of the same copper alloy grade, C70260: TM00 (mill hardened) versus TM04 (mill hardened, full hard). The chemistry is identical, so every difference below comes from the condition. C70260-TM04 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 400 MPa (58 ksi) for C70260-TM00, about 55% more; tensile strength follows at 665 MPa (96.5 ksi) vs 490 MPa (71.1 ksi). In exchange, C70260-TM00 is the more ductile: elongation 15% versus 5% for C70260-TM04, and C70260-TM04 is harder (215 HV vs 150 HV). C70260-TM00 conducts heat better (200 W/m·K vs 176 W/m·K).

C70260-TM00Choose it when the part is bent, formed or impact-loaded.

C70260-TM04Choose it when strength drives the design.

C70260-TM00 vs C70260-TM04: properties

C70260-TM00C70260-TM04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

490 MPa71.1 ksi
665 MPa96.5 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
620 MPa89.9 ksi

Elongation at Break

15%
5%

Shear Strength

305 MPa44.2 ksi
410 MPa59.5 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
255 MPa37 ksi

Hardness, Rockwell B

79 HRB
96 HRB

Hardness, Vickers

150 HV
215 HV

Same in both: Elastic (Young's) Modulus 130 GPa18.9 Msi · Shear Modulus 49 GPa7.1 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.33 · Hardness, Brinell 175 HB

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,085°C1,985 °F · Liquidus Temperature 1,100°C2,012 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
176 W/m·K102 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

53 % IACS
46 % IACS

Electrical Resistivity

3.25×10⁻⁸ Ω·m1.28 µΩ·in
3.75×10⁻⁸ Ω·m1.48 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.24 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
42 / 100

Formability (cold)

80 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70260

C70260-TM00 vs C70260-TM04 — frequently asked

Is C70260-TM04 stronger than C70260-TM00?

Yes. C70260-TM04 has a typical yield strength of 620 MPa (89.9 ksi) against 400 MPa (58 ksi) for C70260-TM00 — about 55% more. Tensile strength is 665 MPa (96.5 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, TM00 or TM04?

TM02 is the default C70260 condition in the FabDigit quote flow (neither TM00 nor TM04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C70260-TM00 or C70260-TM04?

C70260-TM04. Its machinability rates fair (42/100) against poor (34/100) for C70260-TM00.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70260-TM00 and C70260-TM04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.