FabDigitFabDigit

Copper Alloy C70260-TM00 vs C70260-TM02

Copper Alloy · C70260 temper comparison

C70260-TM00 and C70260-TM02 are two conditions of the same copper alloy grade, C70260: TM00 (mill hardened) versus TM02 (mill hardened, half hard). The chemistry is identical, so every difference below comes from the condition. C70260-TM02 is the stronger of the two: yield strength 535 MPa (77.6 ksi) against 400 MPa (58 ksi) for C70260-TM00, about 34% more; tensile strength follows at 595 MPa (86.3 ksi) vs 490 MPa (71.1 ksi). In exchange, C70260-TM00 is the more ductile: elongation 15% versus 9% for C70260-TM02, and C70260-TM02 is harder (185 HV vs 150 HV).

C70260-TM00Choose it when the part is bent, formed or impact-loaded.

C70260-TM02Choose it when strength drives the design.

C70260-TM00 vs C70260-TM02: properties

C70260-TM00C70260-TM02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

490 MPa71.1 ksi
595 MPa86.3 ksi

Yield Strength (0.2% offset)

400 MPa58 ksi
535 MPa77.6 ksi

Elongation at Break

15%
9%

Shear Strength

305 MPa44.2 ksi
370 MPa53.7 ksi

Fatigue Strength (Endurance Limit)

200 MPa29 ksi
230 MPa33.4 ksi

Hardness, Rockwell B

79 HRB
89 HRB

Hardness, Vickers

150 HV
185 HV

Same in both: Elastic (Young's) Modulus 130 GPa18.9 Msi · Shear Modulus 49 GPa7.1 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.33 · Hardness, Brinell 175 HB

Physical

Density and transition temperatures.

Same in both: Density 8.83 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,085°C1,985 °F · Liquidus Temperature 1,100°C2,012 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

200 W/m·K116 BTU/hr·ft·°F
190 W/m·K110 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

53 % IACS
50 % IACS

Electrical Resistivity

3.25×10⁻⁸ Ω·m1.28 µΩ·in
3.45×10⁻⁸ Ω·m1.36 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.24 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
38 / 100

Formability (cold)

80 / 100
65 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Brazeability / Solderability 80 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 60 MJ/kg25,795 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC70260

C70260-TM00 vs C70260-TM02 — frequently asked

Is C70260-TM02 stronger than C70260-TM00?

Yes. C70260-TM02 has a typical yield strength of 535 MPa (77.6 ksi) against 400 MPa (58 ksi) for C70260-TM00 — about 34% more. Tensile strength is 595 MPa (86.3 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, TM00 or TM02?

TM02 is the default C70260 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C70260-TM00 over C70260-TM02?

Pick C70260-TM00 when the part is bent, formed or impact-loaded. Pick C70260-TM02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C70260-TM00 and C70260-TM02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.