Copper Alloy C69400-H02 vs C69400-M20

Copper Alloy · C69400 temper comparison

C69400-H02 and C69400-M20 are two conditions of the same copper alloy grade, C69400: H02 (half hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C69400-H02 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 310 MPa (45 ksi) for C69400-M20, about 34% more; tensile strength follows at 655 MPa (95 ksi) vs 590 MPa (85.6 ksi). In exchange, C69400-M20 is the more ductile: elongation 25% versus 20% for C69400-H02, and C69400-H02 is harder (180 HB vs 155 HB). C69400-M20 runs hotter in service (200°C vs 175°C continuous).

C69400-H02Choose it when strength drives the design.

C69400-M20Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C69400-H02 vs C69400-M20: properties

C69400-H02C69400-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

655 MPa95 ksi
590 MPa85.6 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
310 MPa45 ksi

Elongation at Break

20%
25%

Shear Strength

400 MPa58 ksi
365 MPa52.9 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
205 MPa29.7 ksi

Hardness, Brinell

180 HB
155 HB

Hardness, Rockwell B

85 HRB
78 HRB

Hardness, Vickers

190 HV
165 HV

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 820°C1,508 °F · Liquidus Temperature 917°C1,683 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

28 W/m·K16.2 BTU/hr·ft·°F
28.5 W/m·K16.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
200°C392 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 190 J/g81.7 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

6.6 % IACS
6.7 % IACS

Electrical Resistivity

2.61×10⁻⁷ Ω·m10.3 µΩ·in
2.6×10⁻⁷ Ω·m10.2 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 66 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

95%
90%

Weldability

42 / 100
45 / 100

Formability (cold)

30 / 100
40 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 75 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC69400

C69400-H02 vs C69400-M20 — frequently asked

Is C69400-H02 stronger than C69400-M20?

Yes. C69400-H02 has a typical yield strength of 415 MPa (60.2 ksi) against 310 MPa (45 ksi) for C69400-M20 — about 34% more. Tensile strength is 655 MPa (95 ksi) vs 590 MPa (85.6 ksi).

Which condition does FabDigit quote by default, H02 or M20?

M30 is the default C69400 condition in the FabDigit quote flow (neither H02 nor M20). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C69400-H02 over C69400-M20?

Pick C69400-H02 when strength drives the design. Pick C69400-M20 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C69400-H02 and C69400-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.