FabDigitFabDigit

Copper Alloy C63000-M30 vs C63000-O60

Copper Alloy · C63000 temper comparison

C63000-M30 and C63000-O60 are two conditions of the same copper alloy grade, C63000: M30 (as hot extruded) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C63000-M30 is the stronger of the two: yield strength 345 MPa (50 ksi) against 310 MPa (45 ksi) for C63000-O60, about 11% more; tensile strength follows at 690 MPa (100 ksi) vs 655 MPa (95 ksi). In exchange, C63000-O60 is the more ductile: elongation 25% versus 20% for C63000-M30, and C63000-M30 is harder (170 HB vs 150 HB).

C63000-M30Choose it when strength drives the design.

C63000-O60Choose it when the part is bent, formed or impact-loaded.

C63000-M30 vs C63000-O60: properties

C63000-M30C63000-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

690 MPa100 ksi
655 MPa95 ksi

Yield Strength (0.2% offset)

345 MPa50 ksi
310 MPa45 ksi

Elongation at Break

20%
25%

Reduction in Area

30%
35%

Shear Strength

415 MPa60.2 ksi
400 MPa58 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
220 MPa31.9 ksi

Fracture Toughness (K_IC)

50 MPa·√m45.5 ksi·√in
55 MPa·√m50.1 ksi·√in

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
35 J25.8 ft·lbf

Hardness, Brinell

170 HB
150 HB

Hardness, Rockwell B

85 HRB
78 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.58 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,043°C1,909 °F · Liquidus Temperature 1,054°C1,929 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

38.9 W/m·K22.5 BTU/hr·ft·°F
39.5 W/m·K22.8 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Max Service Temperature (continuous) 300°C572 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7 % IACS
7.2 % IACS

Electrical Resistivity

2.46×10⁻⁷ Ω·m9.69 µΩ·in
2.4×10⁻⁷ Ω·m9.45 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 78 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
34 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
34%

Weldability

68 / 100
70 / 100

Formability (cold)

28 / 100
40 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 3.9 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC63000

C63000-M30 vs C63000-O60 — frequently asked

Is C63000-M30 stronger than C63000-O60?

Yes. C63000-M30 has a typical yield strength of 345 MPa (50 ksi) against 310 MPa (45 ksi) for C63000-O60 — about 11% more. Tensile strength is 690 MPa (100 ksi) vs 655 MPa (95 ksi).

Which condition does FabDigit quote by default, M30 or O60?

HR50 is the default C63000 condition in the FabDigit quote flow (neither M30 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C63000-M30 over C63000-O60?

Pick C63000-M30 when strength drives the design. Pick C63000-O60 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C63000-M30 and C63000-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.