FabDigitFabDigit

Copper Alloy C62200-H04 vs C62200-O60

Copper Alloy · C62200 temper comparison

C62200-H04 and C62200-O60 are two conditions of the same copper alloy grade, C62200: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C62200-H04 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 275 MPa (39.9 ksi) for C62200-O60, about 64% more; tensile strength follows at 700 MPa (102 ksi) vs 585 MPa (84.8 ksi). In exchange, C62200-O60 is the more ductile: elongation 25% versus 12% for C62200-H04, and C62200-H04 is harder (195 HB vs 150 HB). C62200-O60 runs hotter in service (300°C vs 250°C continuous).

C62200-H04Choose it when strength drives the design.

C62200-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C62200-H04 vs C62200-O60: properties

C62200-H04C62200-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
585 MPa84.8 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
275 MPa39.9 ksi

Elongation at Break

12%
25%

Reduction in Area

18%
30%

Shear Strength

440 MPa63.8 ksi
370 MPa53.7 ksi

Fatigue Strength (Endurance Limit)

265 MPa38.4 ksi
230 MPa33.4 ksi

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
20 J14.8 ft·lbf

Hardness, Brinell

195 HB
150 HB

Hardness, Rockwell B

95 HRB
80 HRB

Hardness, Vickers

205 HV
158 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.53 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,027°C1,881 °F · Liquidus Temperature 1,046°C1,915 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
46 W/m·K26.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 215 J/g92.4 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

7 % IACS
7.5 % IACS

Electrical Resistivity

2.46×10⁻⁷ Ω·m9.69 µΩ·in
2.3×10⁻⁷ Ω·m9.06 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
73 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
28%

Weldability

60 / 100
68 / 100

Formability (cold)

20 / 100
45 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.9 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC62200

C62200-H04 vs C62200-O60 — frequently asked

Is C62200-H04 stronger than C62200-O60?

Yes. C62200-H04 has a typical yield strength of 450 MPa (65.3 ksi) against 275 MPa (39.9 ksi) for C62200-O60 — about 64% more. Tensile strength is 700 MPa (102 ksi) vs 585 MPa (84.8 ksi).

Which condition does FabDigit quote by default, H04 or O60?

M30 is the default C62200 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C62200-H04 or C62200-O60?

C62200-H04, by a small margin. Both rate poor for machinability — 33/100 against 28/100 for C62200-O60; for welding the order is C62200-O60 first (good, 68/100) then C62200-H04 (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C62200-H04 and C62200-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.