FabDigitFabDigit

Copper Alloy C62200-H04 vs C62200-M11

Copper Alloy · C62200 temper comparison

C62200-H04 and C62200-M11 are two conditions of the same copper alloy grade, C62200: H04 (full hard) versus M11 (as forged and quenched). The chemistry is identical, so every difference below comes from the condition. C62200-H04 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 310 MPa (45 ksi) for C62200-M11, about 45% more; tensile strength follows at 700 MPa (102 ksi) vs 620 MPa (89.9 ksi). In exchange, C62200-M11 is the more ductile: elongation 18% versus 12% for C62200-H04, and C62200-H04 is harder (195 HB vs 165 HB). C62200-M11 runs hotter in service (300°C vs 250°C continuous).

C62200-H04Choose it when strength drives the design.

C62200-M11Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C62200-H04 vs C62200-M11: properties

C62200-H04C62200-M11

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

700 MPa102 ksi
620 MPa89.9 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
310 MPa45 ksi

Elongation at Break

12%
18%

Reduction in Area

18%
24%

Shear Strength

440 MPa63.8 ksi
390 MPa56.6 ksi

Fatigue Strength (Endurance Limit)

265 MPa38.4 ksi
240 MPa34.8 ksi

Charpy V-Notch Impact (RT)

11 J8.1 ft·lbf
16 J11.8 ft·lbf

Hardness, Brinell

195 HB
165 HB

Hardness, Rockwell B

95 HRB
88 HRB

Hardness, Vickers

205 HV
173 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 108 GPa15.7 Msi · Poisson's Ratio 0.32

Physical

Density and transition temperatures.

Same in both: Density 7.53 g/cm³0.27 lb/in³ · Melting Point (Solidus) 1,027°C1,881 °F · Liquidus Temperature 1,046°C1,915 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

44 W/m·K25.4 BTU/hr·ft·°F
45 W/m·K26 BTU/hr·ft·°F

Max Service Temperature (continuous)

250°C482 °F
300°C572 °F

Same in both: Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 215 J/g92.4 BTU/lb · Min Service Temperature -100°C-148 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 7 % IACS · Electrical Resistivity 2.46×10⁻⁷ Ω·m9.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

70 / 100
72 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.31 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

33 / 100
30 / 100

Machinability Rating (AISI 1212 = 100 %)

33%
30%

Weldability

60 / 100
65 / 100

Formability (cold)

20 / 100
33 / 100

Same in both: Brazeability / Solderability 35 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.9 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC62200

C62200-H04 vs C62200-M11 — frequently asked

Is C62200-H04 stronger than C62200-M11?

Yes. C62200-H04 has a typical yield strength of 450 MPa (65.3 ksi) against 310 MPa (45 ksi) for C62200-M11 — about 45% more. Tensile strength is 700 MPa (102 ksi) vs 620 MPa (89.9 ksi).

Which condition does FabDigit quote by default, H04 or M11?

M30 is the default C62200 condition in the FabDigit quote flow (neither H04 nor M11). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C62200-H04 or C62200-M11?

C62200-M11. Its weldability rates good (65/100) against good (60/100) for C62200-H04.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C62200-H04 and C62200-M11 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.