FabDigitFabDigit

Copper Alloy C61500-H02 vs C61500-O60

Copper Alloy · C61500 temper comparison

C61500-H02 and C61500-O60 are two conditions of the same copper alloy grade, C61500: H02 (half hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C61500-H02 is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 215 MPa (31.2 ksi) for C61500-O60, about 123% more; tensile strength follows at 620 MPa (89.9 ksi) vs 500 MPa (72.5 ksi). In exchange, C61500-O60 is the more ductile: elongation 50% versus 12% for C61500-H02, and C61500-H02 is harder (180 HB vs 130 HB). C61500-O60 runs hotter in service (400°C vs 230°C continuous). On the shop floor, C61500-O60 welds better (very good vs good).

C61500-H02Choose it when strength drives the design.

C61500-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C61500-H02 vs C61500-O60: properties

C61500-H02C61500-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

620 MPa89.9 ksi
500 MPa72.5 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
215 MPa31.2 ksi

Elongation at Break

12%
50%

Shear Strength

380 MPa55.1 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

260 MPa37.7 ksi
235 MPa34.1 ksi

Charpy V-Notch Impact (RT)

30 J22.1 ft·lbf
60 J44.3 ft·lbf

Hardness, Brinell

180 HB
130 HB

Hardness, Rockwell B

88 HRB
70 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.32 · Reduction in Area 45% · Compressive Strength 500 MPa72.5 ksi

Physical

Density and transition temperatures.

Same in both: Density 7.72 g/cm³0.28 lb/in³ · Melting Point (Solidus) 1,045°C1,913 °F · Liquidus Temperature 1,060°C1,940 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

230°C446 °F
400°C752 °F

Same in both: Thermal Conductivity 45 W/m·K26 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.2 µm/m·K9 µin/in·°F · Latent Heat of Fusion 210 J/g90.3 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

10 % IACS
10.5 % IACS

Same in both: Electrical Resistivity 1.64×10⁻⁷ Ω·m6.46 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 82 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

34 / 100
28 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Weldability

60 / 100
70 / 100

Formability (cold)

45 / 100
75 / 100

Same in both: Castability 55 / 100 · Brazeability / Solderability 40 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC61500

C61500-H02 vs C61500-O60 — frequently asked

Is C61500-H02 stronger than C61500-O60?

Yes. C61500-H02 has a typical yield strength of 480 MPa (69.6 ksi) against 215 MPa (31.2 ksi) for C61500-O60 — about 123% more. Tensile strength is 620 MPa (89.9 ksi) vs 500 MPa (72.5 ksi).

Which condition does FabDigit quote by default, H02 or O60?

O60 is the default C61500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C61500-H02 or C61500-O60?

C61500-H02, by a small margin. Both rate poor for machinability — 34/100 against 28/100 for C61500-O60; for welding the order is C61500-O60 first (very good, 70/100) then C61500-H02 (good, 60/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C61500-H02 and C61500-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.