FabDigitFabDigit

Copper Alloy C46200-H04 vs C46200-O60

Copper Alloy · C46200 temper comparison

C46200-H04 and C46200-O60 are two conditions of the same copper alloy grade, C46200: H04 (full hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C46200-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 170 MPa (24.7 ksi) for C46200-O60, about 144% more; tensile strength follows at 560 MPa (81.2 ksi) vs 385 MPa (55.8 ksi). In exchange, C46200-O60 is the more ductile: elongation 47% versus 15% for C46200-H04, and C46200-H04 is harder (180 HB vs 95 HB). C46200-O60 runs hotter in service (250°C vs 150°C continuous). On the shop floor, C46200-H04 machines more easily (52 vs 40 out of 100).

C46200-H04Choose it when strength drives the design, or when the part is machined in volume.

C46200-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C46200-H04 vs C46200-O60: properties

C46200-H04C46200-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

560 MPa81.2 ksi
385 MPa55.8 ksi

Yield Strength (0.2% offset)

415 MPa60.2 ksi
170 MPa24.7 ksi

Elongation at Break

15%
47%

Reduction in Area

32%
55%

Shear Strength

315 MPa45.7 ksi
269 MPa39 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
130 MPa18.9 ksi

Hardness, Brinell

180 HB
95 HB

Hardness, Rockwell B

90 HRB
52 HRB

Hardness, Vickers

190 HV
100 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

52 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

95%
80%

Formability (cold)

18 / 100
60 / 100

Same in both: Weldability 45 / 100 · Castability 55 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.9 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC46200

C46200-H04 vs C46200-O60 — frequently asked

Is C46200-H04 stronger than C46200-O60?

Yes. C46200-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 170 MPa (24.7 ksi) for C46200-O60 — about 144% more. Tensile strength is 560 MPa (81.2 ksi) vs 385 MPa (55.8 ksi).

Which condition does FabDigit quote by default, H04 or O60?

M30 is the default C46200 condition in the FabDigit quote flow (neither H04 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C46200-H04 or C46200-O60?

C46200-H04, by a small margin. Both rate fair for machinability — 52/100 against 40/100 for C46200-O60.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C46200-H04 and C46200-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.