FabDigitFabDigit

Copper Alloy C46200-H02 vs C46200-H04

Copper Alloy · C46200 temper comparison

C46200-H02 and C46200-H04 are two conditions of the same copper alloy grade, C46200: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C46200-H04 is the stronger of the two: yield strength 415 MPa (60.2 ksi) against 360 MPa (52.2 ksi) for C46200-H02, about 15% more; tensile strength follows at 560 MPa (81.2 ksi) vs 470 MPa (68.2 ksi). In exchange, C46200-H02 is the more ductile: elongation 20% versus 15% for C46200-H04, and C46200-H04 is harder (180 HB vs 150 HB). C46200-H02 runs hotter in service (175°C vs 150°C continuous).

C46200-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C46200-H04Choose it when strength drives the design.

C46200-H02 vs C46200-H04: properties

C46200-H02C46200-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

360 MPa52.2 ksi
415 MPa60.2 ksi

Elongation at Break

20%
15%

Reduction in Area

40%
32%

Shear Strength

296 MPa42.9 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
160 MPa23.2 ksi

Hardness, Brinell

150 HB
180 HB

Hardness, Rockwell B

82 HRB
90 HRB

Hardness, Vickers

158 HV
190 HV

Same in both: Elastic (Young's) Modulus 100 GPa14.5 Msi · Shear Modulus 38 GPa5.5 Msi · Bulk Modulus 110 GPa16 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 885°C1,625 °F · Liquidus Temperature 900°C1,652 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.2 µm/m·K11.8 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
52 / 100

Formability (cold)

28 / 100
18 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 95% · Weldability 45 / 100 · Castability 55 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.9 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC46200

C46200-H02 vs C46200-H04 — frequently asked

Is C46200-H04 stronger than C46200-H02?

Yes. C46200-H04 has a typical yield strength of 415 MPa (60.2 ksi) against 360 MPa (52.2 ksi) for C46200-H02 — about 15% more. Tensile strength is 560 MPa (81.2 ksi) vs 470 MPa (68.2 ksi).

Which condition does FabDigit quote by default, H02 or H04?

M30 is the default C46200 condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C46200-H02 over C46200-H04?

Pick C46200-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C46200-H04 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C46200-H02 and C46200-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.