C42200-H02 and C42200-H04 are two conditions of the same copper alloy grade, C42200: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C42200-H04 is the stronger of the two: yield strength 450 MPa (65.3 ksi) against 359 MPa (52.1 ksi) for C42200-H02, about 25% more; tensile strength follows at 490 MPa (71.1 ksi) vs 414 MPa (60 ksi). In exchange, C42200-H02 is the more ductile: elongation 12% versus 5% for C42200-H04, and C42200-H04 is harder (150 HB vs 130 HB). C42200-H02 runs hotter in service (150°C vs 135°C continuous).

C42200-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C42200-H04Choose it when strength drives the design.

C42200-H02 vs C42200-H04: properties

C42200-H02C42200-H04

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

414 MPa60 ksi
490 MPa71.1 ksi

Yield Strength (0.2% offset)

359 MPa52.1 ksi
450 MPa65.3 ksi

Elongation at Break

12%
5%

Shear Strength

285 MPa41.3 ksi
315 MPa45.7 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
170 MPa24.7 ksi

Hardness, Brinell

130 HB
150 HB

Hardness, Rockwell B

70 HRB
78 HRB

Hardness, Vickers

140 HV
162 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.78 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,004°C1,839 °F · Liquidus Temperature 1,027°C1,881 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
135°C275 °F

Same in both: Thermal Conductivity 113 W/m·K65.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 28 % IACS · Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
35 / 100

Formability (cold)

65 / 100
40 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Castability 30 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC42200

C42200-H02 vs C42200-H04 — frequently asked

Is C42200-H04 stronger than C42200-H02?

Yes. C42200-H04 has a typical yield strength of 450 MPa (65.3 ksi) against 359 MPa (52.1 ksi) for C42200-H02 — about 25% more. Tensile strength is 490 MPa (71.1 ksi) vs 414 MPa (60 ksi).

Which condition does FabDigit quote by default, H02 or H04?

H02 is the default C42200 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C42200-H02 or C42200-H04?

C42200-H04. Its machinability rates fair (35/100) against poor (30/100) for C42200-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C42200-H02 and C42200-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.