FabDigitFabDigit

Copper Alloy C42200-H04 vs C42200-H10

Copper Alloy · C42200 temper comparison

C42200-H04 and C42200-H10 are two conditions of the same copper alloy grade, C42200: H04 (full hard) versus H10 (extra spring hard). The chemistry is identical, so every difference below comes from the condition. C42200-H10 is the stronger of the two: yield strength 555 MPa (80.5 ksi) against 450 MPa (65.3 ksi) for C42200-H04, about 23% more; tensile strength follows at 595 MPa (86.3 ksi) vs 490 MPa (71.1 ksi). In exchange, C42200-H04 is the more ductile: elongation 5% versus 2% for C42200-H10, and C42200-H10 is harder (180 HB vs 150 HB). C42200-H04 runs hotter in service (135°C vs 120°C continuous).

C42200-H04Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C42200-H10Choose it when strength drives the design.

C42200-H04 vs C42200-H10: properties

C42200-H04C42200-H10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

490 MPa71.1 ksi
595 MPa86.3 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
555 MPa80.5 ksi

Elongation at Break

5%
2%

Shear Strength

315 MPa45.7 ksi
355 MPa51.5 ksi

Fatigue Strength (Endurance Limit)

170 MPa24.7 ksi
195 MPa28.3 ksi

Hardness, Brinell

150 HB
180 HB

Hardness, Rockwell B

78 HRB
88 HRB

Hardness, Vickers

162 HV
195 HV

Same in both: Elastic (Young's) Modulus 110 GPa16 Msi · Shear Modulus 41 GPa5.9 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.78 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,004°C1,839 °F · Liquidus Temperature 1,027°C1,881 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

135°C275 °F
120°C248 °F

Same in both: Thermal Conductivity 113 W/m·K65.3 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 28 % IACS · Electrical Resistivity 6.2×10⁻⁸ Ω·m2.44 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
40 / 100

Formability (cold)

40 / 100
15 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 30% · Weldability 45 / 100 · Castability 30 / 100 · Brazeability / Solderability 90 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC42200

C42200-H04 vs C42200-H10 — frequently asked

Is C42200-H10 stronger than C42200-H04?

Yes. C42200-H10 has a typical yield strength of 555 MPa (80.5 ksi) against 450 MPa (65.3 ksi) for C42200-H04 — about 23% more. Tensile strength is 595 MPa (86.3 ksi) vs 490 MPa (71.1 ksi).

Which condition does FabDigit quote by default, H04 or H10?

H02 is the default C42200 condition in the FabDigit quote flow (neither H04 nor H10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C42200-H04 or C42200-H10?

C42200-H10, by a small margin. Both rate fair for machinability — 40/100 against 35/100 for C42200-H04.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C42200-H04 and C42200-H10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.