C33200-H04 and C33200-H55 are two conditions of the same copper alloy grade, C33200: H04 (full hard) versus H55 (light drawn). The chemistry is identical, so every difference below comes from the condition. C33200-H04 is the stronger of the two: yield strength 370 MPa (53.7 ksi) against 240 MPa (34.8 ksi) for C33200-H55, about 54% more; tensile strength follows at 470 MPa (68.2 ksi) vs 380 MPa (55.1 ksi). In exchange, C33200-H55 is the more ductile: elongation 30% versus 12% for C33200-H04, and C33200-H04 is harder (130 HB vs 95 HB).

C33200-H04Choose it when strength drives the design.

C33200-H55Choose it when the part is bent, formed or impact-loaded.

C33200-H04 vs C33200-H55: properties

C33200-H04C33200-H55

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

470 MPa68.2 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
240 MPa34.8 ksi

Elongation at Break

12%
30%

Shear Strength

285 MPa41.3 ksi
260 MPa37.7 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
115 MPa16.7 ksi

Hardness, Brinell

130 HB
95 HB

Hardness, Rockwell B

68 HRB
55 HRB

Same in both: Elastic (Young's) Modulus 103 GPa14.9 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.47 g/cm³0.31 lb/in³ · Melting Point (Solidus) 899°C1,650 °F · Liquidus Temperature 932°C1,710 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 377 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.2 µm/m·K11.2 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 26 % IACS · Electrical Resistivity 6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

82%
80%

Formability (cold)

30 / 100
50 / 100

Same in both: Machinability 82 / 100 · Weldability 20 / 100 · Brazeability / Solderability 88 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC33200

C33200-H04 vs C33200-H55 — frequently asked

Is C33200-H04 stronger than C33200-H55?

Yes. C33200-H04 has a typical yield strength of 370 MPa (53.7 ksi) against 240 MPa (34.8 ksi) for C33200-H55 — about 54% more. Tensile strength is 470 MPa (68.2 ksi) vs 380 MPa (55.1 ksi).

Which condition does FabDigit quote by default, H04 or H55?

H80 is the default C33200 condition in the FabDigit quote flow (neither H04 nor H55). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C33200-H04 over C33200-H55?

Pick C33200-H04 when strength drives the design. Pick C33200-H55 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C33200-H04 and C33200-H55 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.