C27400-H02 and C27400-H06 are two conditions of the same copper alloy grade, C27400: H02 (half hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C27400-H06 is the stronger of the two: yield strength 455 MPa (66 ksi) against 340 MPa (49.3 ksi) for C27400-H02, about 34% more; tensile strength follows at 570 MPa (82.7 ksi) vs 425 MPa (61.6 ksi). In exchange, C27400-H02 is the more ductile: elongation 23% versus 5% for C27400-H06, and C27400-H06 is harder (175 HB vs 125 HB). C27400-H02 runs hotter in service (150°C vs 130°C continuous).

C27400-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C27400-H06Choose it when strength drives the design.

C27400-H02 vs C27400-H06: properties

C27400-H02C27400-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

425 MPa61.6 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

340 MPa49.3 ksi
455 MPa66 ksi

Elongation at Break

23%
5%

Shear Strength

290 MPa42.1 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

125 MPa18.1 ksi
145 MPa21 ksi

Hardness, Brinell

125 HB
175 HB

Hardness, Rockwell B

70 HRB
88 HRB

Hardness, Vickers

130 HV
185 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.44 g/cm³0.3 lb/in³ · Melting Point (Solidus) 900°C1,652 °F · Liquidus Temperature 930°C1,706 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

150°C302 °F
130°C266 °F

Same in both: Thermal Conductivity 116 W/m·K67 BTU/hr·ft·°F · Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 20.5 µm/m·K11.4 µin/in·°F · Latent Heat of Fusion 170 J/g73.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 27 % IACS · Electrical Resistivity 6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.27 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

30%
35%

Formability (cold)

60 / 100
22 / 100

Same in both: Machinability 32 / 100 · Weldability 45 / 100 · Brazeability / Solderability 90 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 45%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC27400

C27400-H02 vs C27400-H06 — frequently asked

Is C27400-H06 stronger than C27400-H02?

Yes. C27400-H06 has a typical yield strength of 455 MPa (66 ksi) against 340 MPa (49.3 ksi) for C27400-H02 — about 34% more. Tensile strength is 570 MPa (82.7 ksi) vs 425 MPa (61.6 ksi).

Which condition does FabDigit quote by default, H02 or H06?

H02 is the default C27400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C27400-H02 over C27400-H06?

Pick C27400-H02 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C27400-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C27400-H02 and C27400-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.