C24000-H02 and C24000-M20 are two conditions of the same copper alloy grade, C24000: H02 (half hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C24000-H02 is the stronger of the two: yield strength 310 MPa (45 ksi) against 105 MPa (15.2 ksi) for C24000-M20, about 195% more; tensile strength follows at 395 MPa (57.3 ksi) vs 290 MPa (42.1 ksi). In exchange, C24000-M20 is the more ductile: elongation 50% versus 30% for C24000-H02, and C24000-H02 is harder (120 HB vs 58 HB). C24000-M20 runs hotter in service (200°C vs 175°C continuous).

C24000-H02Choose it when strength drives the design.

C24000-M20Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C24000-H02 vs C24000-M20: properties

C24000-H02C24000-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

395 MPa57.3 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
105 MPa15.2 ksi

Elongation at Break

30%
50%

Shear Strength

270 MPa39.2 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

130 MPa18.9 ksi
105 MPa15.2 ksi

Hardness, Brinell

120 HB
58 HB

Hardness, Vickers

130 HV
65 HV

Same in both: Elastic (Young's) Modulus 105 GPa15.2 Msi · Shear Modulus 39 GPa5.7 Msi · Bulk Modulus 112 GPa16.2 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.67 g/cm³0.31 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,030°C1,886 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

175°C347 °F
200°C392 °F

Same in both: Thermal Conductivity 138 W/m·K79.7 BTU/hr·ft·°F · Specific Heat Capacity 375 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 18.4 µm/m·K10.2 µin/in·°F · Latent Heat of Fusion 180 J/g77.4 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 32 % IACS · Electrical Resistivity 5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.26 V · Corrosion Resistance 60 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

32%
30%

Formability (cold)

65 / 100
88 / 100

Same in both: Machinability 32 / 100 · Weldability 45 / 100 · Castability 30 / 100 · Brazeability / Solderability 90 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 58 MJ/kg24,936 BTU/lb · Embodied Carbon (primary production) 4 kg CO₂/kg · Embodied Water 400 L/kg47.9 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC24000

C24000-H02 vs C24000-M20 — frequently asked

Is C24000-H02 stronger than C24000-M20?

Yes. C24000-H02 has a typical yield strength of 310 MPa (45 ksi) against 105 MPa (15.2 ksi) for C24000-M20 — about 195% more. Tensile strength is 395 MPa (57.3 ksi) vs 290 MPa (42.1 ksi).

Which condition does FabDigit quote by default, H02 or M20?

OS050 is the default C24000 condition in the FabDigit quote flow (neither H02 nor M20). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C24000-H02 over C24000-M20?

Pick C24000-H02 when strength drives the design. Pick C24000-M20 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C24000-H02 and C24000-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.