FabDigitFabDigit

Copper Alloy C23000 vs C33000

Copper Alloy · grade comparison

Copper Alloy C23000 and C33000 are both copper alloy grades. C33000 is the stronger of the two: yield strength 110 MPa (16 ksi) against 85 MPa (12.3 ksi) for C23000, about 29% more; tensile strength follows at 340 MPa (49.3 ksi) vs 280 MPa (40.6 ksi). C33000 is the more ductile: elongation 55% versus 45% for C23000, and C33000 is harder (55 HB vs 46 HB). C33000 is lighter (8.47 g/cm³ vs 8.75 g/cm³ for C23000) and C23000 is stiffer (117 GPa vs 103 GPa). On the shop floor, C33000 machines more easily (very good vs poor) and C23000 welds better (good vs poor).

C23000Choose it when it will be welded.

C33000Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C23000 vs C33000: properties

C23000C33000

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
103 GPa14.9 Msi

Shear Modulus

44 GPa6.4 Msi
39 GPa5.7 Msi

Bulk Modulus

120 GPa17.4 Msi
111 GPa16.1 Msi

Tensile Strength (Ultimate)

280 MPa40.6 ksi
340 MPa49.3 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
110 MPa16 ksi

Elongation at Break

45%
55%

Reduction in Area

65%
62%

Shear Strength

200 MPa29 ksi
220 MPa31.9 ksi

Fatigue Strength (Endurance Limit)

96 MPa13.9 ksi
105 MPa15.2 ksi

Charpy V-Notch Impact (RT)

60 J44.3 ft·lbf
55 J40.6 ft·lbf

Hardness, Brinell

46 HB
55 HB

Hardness, Vickers

—
58 HV

Same in both: Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Density

8.75 g/cm³0.32 lb/in³
8.47 g/cm³0.31 lb/in³

Melting Point (Solidus)

990°C1,814 °F
899°C1,650 °F

Liquidus Temperature

1,025°C1,877 °F
954°C1,749 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

159 W/m·K91.9 BTU/hr·ft·°F
121 W/m·K69.9 BTU/hr·ft·°F

Specific Heat Capacity

377 J/kg·K0.09 BTU/lb·°F
375 J/kg·K0.09 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

18.7 µm/m·K10.4 µin/in·°F
20.2 µm/m·K11.2 µin/in·°F

Latent Heat of Fusion

195 J/g83.8 BTU/lb
170 J/g73.1 BTU/lb

Same in both: Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

37 % IACS
26 % IACS

Electrical Resistivity

4.66×10⁻⁸ Ω·m1.83 µΩ·in
6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.27 V
-0.25 V

Corrosion Resistance

63 / 100
55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
180%

Weldability

55 / 100
25 / 100

Formability (cold)

95 / 100
85 / 100

Castability

40 / 100
—

Brazeability / Solderability

92 / 100
85 / 100

Polishability

88 / 100
80 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

62 MJ/kg26,655 BTU/lb
55 MJ/kg23,646 BTU/lb

Embodied Carbon (primary production)

4 kg CO₂/kg
3.6 kg CO₂/kg

Embodied Water

260 L/kg31.2 gal/lb
180 L/kg21.6 gal/lb

Typical Recycled Content

45%
50%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

32 kN·m/kg
40 kN·m/kg

Specific Stiffness (E / density)

13.4 MN·m/kg
12.2 MN·m/kg

Modulus of Resilience

31 kJ/m³
59 kJ/m³

Thermal Diffusivity

48.2 mm²/s
38.1 mm²/s

Same in both: Thermal Shock Resistance Index 20

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC33000C23000

Manufacturing and finishing

CapabilityC23000C33000
CNC machining—Yes
Sheet metal—Yes
Default condition—O
Relative cost$$$$ High$$$$ High
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
Chrome Plating—Yes
Electropolishing—Yes
Nickel Plating—Yes
Painting—Yes
Tin Plating—Yes

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C23000 vs C33000 — frequently asked

Is C33000 stronger than C23000?

Yes. C33000 has a typical yield strength of 110 MPa (16 ksi) against 85 MPa (12.3 ksi) for C23000 — about 29% more. Tensile strength is 340 MPa (49.3 ksi) vs 280 MPa (40.6 ksi).

Which is cheaper, C23000 or C33000?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, C23000 or C33000?

C33000. Its machinability rates very good (70/100) against poor (28/100) for C23000; for welding the order is C23000 first (good, 55/100) then C33000 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C23000 and C33000 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.