FabDigitFabDigit

Copper Alloy C19410-H02 vs C19410-H06

Copper Alloy · C19410 temper comparison

C19410-H02 and C19410-H06 are two conditions of the same copper alloy grade, C19410: H02 (half hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C19410-H06 is the stronger of the two: yield strength 455 MPa (66 ksi) against 370 MPa (53.7 ksi) for C19410-H02, about 23% more; tensile strength follows at 480 MPa (69.6 ksi) vs 415 MPa (60.2 ksi). In exchange, C19410-H02 is the more ductile: elongation 8% versus 3% for C19410-H06, and C19410-H06 is harder (140 HB vs 118 HB). C19410-H02 runs hotter in service (200°C vs 175°C continuous). On the shop floor, C19410-H02 welds better (good vs fair).

C19410-H02Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19410-H06Choose it when strength drives the design.

C19410-H02 vs C19410-H06: properties

C19410-H02C19410-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

121 GPa17.5 Msi
122 GPa17.7 Msi

Tensile Strength (Ultimate)

415 MPa60.2 ksi
480 MPa69.6 ksi

Yield Strength (0.2% offset)

370 MPa53.7 ksi
455 MPa66 ksi

Elongation at Break

8%
3%

Reduction in Area

45%
25%

Shear Strength

255 MPa37 ksi
290 MPa42.1 ksi

Fatigue Strength (Endurance Limit)

150 MPa21.8 ksi
165 MPa23.9 ksi

Hardness, Brinell

118 HB
140 HB

Hardness, Rockwell B

62 HRB
76 HRB

Hardness, Vickers

125 HV
148 HV

Same in both: Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 130 GPa18.9 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,085°C1,985 °F · Liquidus Temperature 1,090°C1,994 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

260 W/m·K150 BTU/hr·ft·°F
255 W/m·K147 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
175°C347 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.6 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

62 % IACS
61 % IACS

Electrical Resistivity

2.78×10⁻⁸ Ω·m1.09 µΩ·in
2.83×10⁻⁸ Ω·m1.11 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

22 / 100
27 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
24%

Weldability

55 / 100
45 / 100

Formability (cold)

65 / 100
40 / 100

Same in both: Brazeability / Solderability 90 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 62 MJ/kg26,655 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19410

C19410-H02 vs C19410-H06 — frequently asked

Is C19410-H06 stronger than C19410-H02?

Yes. C19410-H06 has a typical yield strength of 455 MPa (66 ksi) against 370 MPa (53.7 ksi) for C19410-H02 — about 23% more. Tensile strength is 480 MPa (69.6 ksi) vs 415 MPa (60.2 ksi).

Which condition does FabDigit quote by default, H02 or H06?

H02 is the default C19410 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C19410-H02 or C19410-H06?

C19410-H06, by a small margin. Both rate poor for machinability — 27/100 against 22/100 for C19410-H02; for welding the order is C19410-H02 first (good, 55/100) then C19410-H06 (fair, 45/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19410-H02 and C19410-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.