C19200-H06 and C19200-O60 are two conditions of the same copper alloy grade, C19200: H06 (extra hard) versus O60 (soft annealed). The chemistry is identical, so every difference below comes from the condition. C19200-H06 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 85 MPa (12.3 ksi) for C19200-O60, about 4.5 times as much; tensile strength follows at 400 MPa (58 ksi) vs 260 MPa (37.7 ksi). In exchange, C19200-O60 is the more ductile: elongation 40% versus 3% for C19200-H06, and C19200-H06 is harder (115 HB vs 50 HB). C19200-O60 runs hotter in service (250°C vs 190°C continuous).

C19200-H06Choose it when strength drives the design.

C19200-O60Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19200-H06 vs C19200-O60: properties

C19200-H06C19200-O60

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
85 MPa12.3 ksi

Elongation at Break

3%
40%

Shear Strength

240 MPa34.8 ksi
160 MPa23.2 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
80 MPa11.6 ksi

Hardness, Brinell

115 HB
50 HB

Hardness, Vickers

130 HV
55 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 133 GPa19.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,075°C1,967 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

208 W/m·K120 BTU/hr·ft·°F
220 W/m·K127 BTU/hr·ft·°F

Max Service Temperature (continuous)

190°C374 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

57 % IACS
62 % IACS

Electrical Resistivity

3.02×10⁻⁸ Ω·m1.19 µΩ·in
2.78×10⁻⁸ Ω·m1.09 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

44 / 100
92 / 100

Same in both: Machinability 28 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 60 / 100 · Castability 35 / 100 · Brazeability / Solderability 95 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19200

C19200-H06 vs C19200-O60 — frequently asked

Is C19200-H06 stronger than C19200-O60?

Yes. C19200-H06 has a typical yield strength of 380 MPa (55.1 ksi) against 85 MPa (12.3 ksi) for C19200-O60 — about 4.5 times as much. Tensile strength is 400 MPa (58 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, H06 or O60?

H55 is the default C19200 condition in the FabDigit quote flow (neither H06 nor O60). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C19200-H06 over C19200-O60?

Pick C19200-H06 when strength drives the design. Pick C19200-O60 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19200-H06 and C19200-O60 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.