FabDigitFabDigit

Copper Alloy C19200-H01 vs C19200-H06

Copper Alloy · C19200 temper comparison

C19200-H01 and C19200-H06 are two conditions of the same copper alloy grade, C19200: H01 (quarter hard) versus H06 (extra hard). The chemistry is identical, so every difference below comes from the condition. C19200-H06 is the stronger of the two: yield strength 380 MPa (55.1 ksi) against 265 MPa (38.4 ksi) for C19200-H01, about 43% more; tensile strength follows at 400 MPa (58 ksi) vs 305 MPa (44.2 ksi). In exchange, C19200-H01 is the more ductile: elongation 12% versus 3% for C19200-H06, and C19200-H06 is harder (115 HB vs 85 HB). C19200-H01 runs hotter in service (210°C vs 190°C continuous).

C19200-H01Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C19200-H06Choose it when strength drives the design.

C19200-H01 vs C19200-H06: properties

C19200-H01C19200-H06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

305 MPa44.2 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

265 MPa38.4 ksi
380 MPa55.1 ksi

Elongation at Break

12%
3%

Shear Strength

195 MPa28.3 ksi
240 MPa34.8 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
135 MPa19.6 ksi

Hardness, Brinell

85 HB
115 HB

Hardness, Vickers

95 HV
130 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 133 GPa19.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 55%

Physical

Density and transition temperatures.

Same in both: Density 8.91 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,075°C1,967 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

215 W/m·K124 BTU/hr·ft·°F
208 W/m·K120 BTU/hr·ft·°F

Max Service Temperature (continuous)

210°C410 °F
190°C374 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

60 % IACS
57 % IACS

Electrical Resistivity

2.87×10⁻⁸ Ω·m1.13 µΩ·in
3.02×10⁻⁸ Ω·m1.19 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

78 / 100
44 / 100

Same in both: Machinability 28 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 60 / 100 · Castability 35 / 100 · Brazeability / Solderability 95 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19200

C19200-H01 vs C19200-H06 — frequently asked

Is C19200-H06 stronger than C19200-H01?

Yes. C19200-H06 has a typical yield strength of 380 MPa (55.1 ksi) against 265 MPa (38.4 ksi) for C19200-H01 — about 43% more. Tensile strength is 400 MPa (58 ksi) vs 305 MPa (44.2 ksi).

Which condition does FabDigit quote by default, H01 or H06?

H55 is the default C19200 condition in the FabDigit quote flow (neither H01 nor H06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C19200-H01 over C19200-H06?

Pick C19200-H01 when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C19200-H06 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19200-H01 and C19200-H06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.