C15900-H08 and C15900-HIP are two conditions of the same copper alloy grade, C15900: H08 (spring hard) versus HIP (hot isostatic pressed). The chemistry is identical, so every difference below comes from the condition. C15900-H08 is the stronger of the two: yield strength 570 MPa (82.7 ksi) against 310 MPa (45 ksi) for C15900-HIP, about 84% more; tensile strength follows at 610 MPa (88.5 ksi) vs 400 MPa (58 ksi). In exchange, C15900-HIP is the more ductile: elongation 22% versus 8% for C15900-H08, and C15900-H08 is harder (160 HB vs 105 HB). C15900-HIP runs hotter in service (550°C vs 450°C continuous). On the shop floor, C15900-HIP machines more easily (fair vs poor).

C15900-H08Choose it when strength drives the design.

C15900-HIPChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C15900-H08 vs C15900-HIP: properties

C15900-H08C15900-HIP

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

130 GPa18.9 Msi
128 GPa18.6 Msi

Tensile Strength (Ultimate)

610 MPa88.5 ksi
400 MPa58 ksi

Yield Strength (0.2% offset)

570 MPa82.7 ksi
310 MPa45 ksi

Elongation at Break

8%
22%

Reduction in Area

55%
72%

Shear Strength

355 MPa51.5 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
165 MPa23.9 ksi

Hardness, Brinell

160 HB
105 HB

Hardness, Rockwell B

84 HRB
60 HRB

Hardness, Vickers

168 HV
110 HV

Same in both: Shear Modulus 48 GPa7 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.86 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

325 W/m·K188 BTU/hr·ft·°F
335 W/m·K194 BTU/hr·ft·°F

Max Service Temperature (continuous)

450°C842 °F
550°C1,022 °F

Same in both: Specific Heat Capacity 380 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 16.6 µm/m·K9.2 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

84 % IACS
86 % IACS

Electrical Resistivity

2.05×10⁻⁸ Ω·m0.807 µΩ·in
2.01×10⁻⁸ Ω·m0.791 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
40 / 100

Machinability Rating (AISI 1212 = 100 %)

18%
24%

Weldability

20 / 100
28 / 100

Formability (cold)

20 / 100
55 / 100

Same in both: Brazeability / Solderability 85 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 65 MJ/kg27,945 BTU/lb · Embodied Carbon (primary production) 4.2 kg CO₂/kg · Embodied Water 320 L/kg38.3 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC15900

C15900-H08 vs C15900-HIP — frequently asked

Is C15900-H08 stronger than C15900-HIP?

Yes. C15900-H08 has a typical yield strength of 570 MPa (82.7 ksi) against 310 MPa (45 ksi) for C15900-HIP — about 84% more. Tensile strength is 610 MPa (88.5 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, H08 or HIP?

H04 is the default C15900 condition in the FabDigit quote flow (neither H08 nor HIP). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C15900-H08 or C15900-HIP?

C15900-HIP. Its machinability rates fair (40/100) against poor (30/100) for C15900-H08; for welding the order is C15900-HIP first (poor, 28/100) then C15900-H08 (poor, 20/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C15900-H08 and C15900-HIP side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.