FabDigitFabDigit

Copper Alloy C11400 vs C12200

Copper Alloy · grade comparison

Copper Alloy C11400 and C12200 are both copper alloy grades. C11400 is the stronger of the two: yield strength 310 MPa (45 ksi) against 76 MPa (11 ksi) for C12200, about 4.1 times as much; tensile strength follows at 345 MPa (50 ksi) vs 235 MPa (34.1 ksi). In exchange, C12200 is the more ductile: elongation 45% versus 6% for C11400, and C11400 is harder (90 HB vs 45 HB). C12200 runs hotter in service (200°C vs 180°C continuous) and C11400 conducts heat better (388 W/m·K vs 339 W/m·K). On the shop floor, C12200 welds better (excellent vs poor).

C11400Choose it when strength drives the design.

C12200Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C11400 vs C12200: properties

C11400C12200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
235 MPa34.1 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
76 MPa11 ksi

Elongation at Break

6%
45%

Shear Strength

193 MPa28 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
76 MPa11 ksi

Hardness, Brinell

90 HB
45 HB

Hardness, Rockwell B

40 HRB
—

Hardness, Vickers

105 HV
—

Reduction in Area

—
75%

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Density

8.89 g/cm³0.32 lb/in³
8.94 g/cm³0.32 lb/in³

Melting Point (Solidus)

1,065°C1,949 °F
1,083°C1,981 °F

Same in both: Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

388 W/m·K224 BTU/hr·ft·°F
339 W/m·K196 BTU/hr·ft·°F

Max Service Temperature (continuous)

180°C356 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

98 % IACS
85 % IACS

Electrical Resistivity

1.76×10⁻⁸ Ω·m0.693 µΩ·in
2.03×10⁻⁸ Ω·m0.799 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.25 V
-0.3 V

Same in both: Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
20 / 100

Weldability

30 / 100
85 / 100

Formability (cold)

45 / 100
98 / 100

Castability

40 / 100
—

Brazeability / Solderability

90 / 100
100 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

3.5 kg CO₂/kg
3.8 kg CO₂/kg

Same in both: Embodied Energy (primary production) 55 MJ/kg23,646 BTU/lb · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 35%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

39 kN·m/kg
26 kN·m/kg

Specific Stiffness (E / density)

13.2 MN·m/kg
13.1 MN·m/kg

Modulus of Resilience

411 kJ/m³
25 kJ/m³

Thermal Diffusivity

113.4 mm²/s
98.5 mm²/s

Thermal Shock Resistance Index

67
40

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC12200C11400

Manufacturing and finishing

CapabilityC11400C12200
CNC machining—Yes
Sheet metal—Yes
Default condition—O
Relative cost$$$$ High$$$$ High
Min. machined wall—0.8 mm
Best machined surface—Ra 1.6 µm
Chrome Plating—Yes
Electropolishing—Yes
Nickel Plating—Yes
Painting—Yes
Tin Plating—Yes

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C11400 vs C12200 — frequently asked

Is C11400 stronger than C12200?

Yes. C11400 has a typical yield strength of 310 MPa (45 ksi) against 76 MPa (11 ksi) for C12200 — about 4.1 times as much. Tensile strength is 345 MPa (50 ksi) vs 235 MPa (34.1 ksi).

Which is cheaper, C11400 or C12200?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which is easier to machine, C11400 or C12200?

C11400, by a small margin. Both rate poor for machinability — 25/100 against 20/100 for C12200; for welding the order is C12200 first (excellent, 85/100) then C11400 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C11400 and C12200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.