FabDigitFabDigit

Copper Alloy C11000 vs C1220

Copper Alloy · grade comparison

Copper Alloy C11000 and C1220 are both copper alloy grades. Both yield at about 69 MPa — strength does not separate them. C11000 runs hotter in service (250°C vs 200°C continuous) and C11000 conducts heat better (391 W/m·K vs 339 W/m·K). On the shop floor, C1220 welds better (very good vs fair).

C11000Choose it when the part sees heat.

C1220Choose it when it will be welded.

C11000 vs C1220: properties

C11000C1220

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

221 MPa32.1 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

69 MPa10 ksi
70 MPa10.2 ksi

Charpy V-Notch Impact (RT)

—
60 J44.3 ft·lbf

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Elongation at Break 45% · Reduction in Area 75% · Shear Strength 152 MPa22 ksi · Fatigue Strength (Endurance Limit) 76 MPa11 ksi · Hardness, Brinell 45 HB · Hardness, Vickers 50 HV

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

391 W/m·K226 BTU/hr·ft·°F
339 W/m·K196 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

17 µm/m·K9.4 µin/in·°F
17.6 µm/m·K9.8 µin/in·°F

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

101 % IACS
85 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.673 µΩ·in
2.03×10⁻⁸ Ω·m0.799 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.32 V
-0.22 V

Corrosion Resistance

60 / 100
68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Weldability

35 / 100
80 / 100

Brazeability / Solderability

92 / 100
100 / 100

Polishability

85 / 100
70 / 100

Same in both: Machinability 25 / 100 · Machinability Rating (AISI 1212 = 100 %) 20% · Formability (cold) 98 / 100 · Castability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

53 MJ/kg22,786 BTU/lb
57 MJ/kg24,506 BTU/lb

Embodied Carbon (primary production)

3.6 kg CO₂/kg
3.8 kg CO₂/kg

Embodied Water

260 L/kg31.2 gal/lb
300 L/kg35.9 gal/lb

Same in both: Typical Recycled Content 35%

Common Calculations

Ratios derived from the values above.

Modulus of Resilience

20 kJ/m³
21 kJ/m³

Thermal Diffusivity

113.6 mm²/s
98.5 mm²/s

Thermal Shock Resistance Index

43
37

Same in both: Specific Strength (UTS / density) 25 kN·m/kg · Specific Stiffness (E / density) 13.1 MN·m/kg

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC11000C1220

Manufacturing and finishing

CapabilityC11000C1220
CNC machiningYes—
Sheet metalYes—
3D printingYes—
Default conditionO—
Relative cost$$$$ High$$$$ High
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
Chrome PlatingYes—
ElectropolishingYes—
Nickel PlatingYes—
PaintingYes—
Tin PlatingYes—

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C11000 vs C1220 — frequently asked

What is the difference between C11000 and C1220?

Copper Alloy C11000 and C1220 are both copper alloy grades. Both yield at about 69 MPa — strength does not separate them. C11000 runs hotter in service (250°C vs 200°C continuous) and C11000 conducts heat better (391 W/m·K vs 339 W/m·K).

Which is cheaper, C11000 or C1220?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, C11000 or C1220?

C1220. Its weldability rates very good (80/100) against fair (35/100) for C11000.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C11000 and C1220 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.