FabDigitFabDigit

Copper Alloy C11000 vs C80100

Copper Alloy · grade comparison

Copper Alloy C11000 and C80100 are both copper alloy grades. C11000 is the stronger of the two: yield strength 69 MPa (10 ksi) against 62 MPa (8.99 ksi) for C80100, about 11% more; tensile strength follows at 221 MPa (32.1 ksi) vs 172 MPa (24.9 ksi). C11000 is the more ductile: elongation 45% versus 40% for C80100. C11000 runs hotter in service (250°C vs 200°C continuous). On the shop floor, C80100 welds better (good vs fair).

C11000Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

C80100Choose it when it will be welded.

C11000 vs C80100: properties

C11000C80100

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

221 MPa32.1 ksi
172 MPa24.9 ksi

Yield Strength (0.2% offset)

69 MPa10 ksi
62 MPa9 ksi

Elongation at Break

45%
40%

Reduction in Area

75%
45%

Shear Strength

152 MPa22 ksi
130 MPa18.9 ksi

Fatigue Strength (Endurance Limit)

76 MPa11 ksi
62 MPa9 ksi

Hardness, Brinell

45 HB
44 HB

Hardness, Vickers

50 HV
48 HV

Charpy V-Notch Impact (RT)

—
60 J44.3 ft·lbf

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,065°C1,949 °F
1,083°C1,981 °F

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Min Service Temperature

-200°C-328 °F
-269°C-452 °F

Same in both: Thermal Conductivity 391 W/m·K226 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

101 % IACS
100 % IACS

Electrical Resistivity

1.71×10⁻⁸ Ω·m0.673 µΩ·in
1.72×10⁻⁸ Ω·m0.677 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.32 V
-0.22 V

Corrosion Resistance

60 / 100
62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
22 / 100

Weldability

35 / 100
55 / 100

Formability (cold)

98 / 100
85 / 100

Castability

40 / 100
30 / 100

Polishability

85 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Brazeability / Solderability 92 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

53 MJ/kg22,786 BTU/lb
57 MJ/kg24,506 BTU/lb

Embodied Carbon (primary production)

3.6 kg CO₂/kg
4 kg CO₂/kg

Embodied Water

260 L/kg31.2 gal/lb
300 L/kg35.9 gal/lb

Typical Recycled Content

35%
20%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

25 kN·m/kg
19 kN·m/kg

Modulus of Resilience

20 kJ/m³
16 kJ/m³

Thermal Shock Resistance Index

43
34

Same in both: Specific Stiffness (E / density) 13.1 MN·m/kg · Thermal Diffusivity 113.6 mm²/s

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC11000C80100

Manufacturing and finishing

CapabilityC11000C80100
CNC machiningYes—
Sheet metalYes—
3D printingYes—
Default conditionO—
Relative cost$$$$ High$$$$ High
Min. machined wall0.8 mm—
Best machined surfaceRa 1.6 µm—
Chrome PlatingYes—
ElectropolishingYes—
Nickel PlatingYes—
PaintingYes—
Tin PlatingYes—

They share 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C11000 vs C80100 — frequently asked

Is C11000 stronger than C80100?

Yes. C11000 has a typical yield strength of 69 MPa (10 ksi) against 62 MPa (8.99 ksi) for C80100 — about 11% more. Tensile strength is 221 MPa (32.1 ksi) vs 172 MPa (24.9 ksi).

Which is cheaper, C11000 or C80100?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, C11000 or C80100?

C80100. Its weldability rates good (55/100) against fair (35/100) for C11000.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C11000 and C80100 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.