Copper Alloy C10800-H02 vs C10800-H04
Copper Alloy · C10800 temper comparison
C10800-H02 and C10800-H04 are two conditions of the same copper alloy grade, C10800: H02 (half hard) versus H04 (full hard). The chemistry is identical, so every difference below comes from the condition. C10800-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 250 MPa (36.3 ksi) for C10800-H02, about 24% more; tensile strength follows at 345 MPa (50 ksi) vs 290 MPa (42.1 ksi). In exchange, C10800-H02 is the more ductile: elongation 14% versus 6% for C10800-H04, and C10800-H04 is harder (95 HB vs 85 HB). On the shop floor, C10800-H02 welds better (80 vs 70 out of 100).
C10800-H02Choose it when the part is bent, formed or impact-loaded, or when it will be welded.
C10800-H04Choose it when strength drives the design.
C10800-H02 vs C10800-H04: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Reduction in Area
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Hardness, Vickers 48 HV
Physical
Density and transition temperatures.
Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -269°C-452 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Same in both: Electrical Resistivity 1.76×10⁻⁸ Ω·m0.693 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 62 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Weldability
Formability (cold)
Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Brazeability / Solderability 95 / 100 · Polishability 85 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 15%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C10800-H02 vs C10800-H04 — frequently asked
Is C10800-H04 stronger than C10800-H02?
Yes. C10800-H04 has a typical yield strength of 310 MPa (45 ksi) against 250 MPa (36.3 ksi) for C10800-H02 — about 24% more. Tensile strength is 345 MPa (50 ksi) vs 290 MPa (42.1 ksi).
Which condition does FabDigit quote by default, H02 or H04?
OS050 is the default C10800 condition in the FabDigit quote flow (neither H02 nor H04). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, C10800-H02 or C10800-H04?
C10800-H04, by a small margin. Both rate fair for machinability — 45/100 against 38/100 for C10800-H02; for welding the order is C10800-H02 first (very good, 80/100) then C10800-H04 (very good, 70/100).
Ready to make it?
Upload a CAD file and FabDigit prices the part in C10800-H02 and C10800-H04 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
