FabDigitFabDigit

Copper Alloy C10400-H04 vs C10400-M20

Copper Alloy · C10400 temper comparison

C10400-H04 and C10400-M20 are two conditions of the same copper alloy grade, C10400: H04 (full hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C10400-H04 is the stronger of the two: yield strength 310 MPa (45 ksi) against 90 MPa (13.1 ksi) for C10400-M20, about 3.4 times as much; tensile strength follows at 345 MPa (50 ksi) vs 235 MPa (34.1 ksi). In exchange, C10400-M20 is the more ductile: elongation 45% versus 6% for C10400-H04, and C10400-H04 is harder (95 HB vs 45 HB). C10400-M20 runs hotter in service (350°C vs 230°C continuous). On the shop floor, C10400-H04 machines more easily (30 vs 20 out of 100).

C10400-H04Choose it when strength drives the design, or when the part is machined in volume.

C10400-M20Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C10400-H04 vs C10400-M20: properties

C10400-H04C10400-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

345 MPa50 ksi
235 MPa34.1 ksi

Yield Strength (0.2% offset)

310 MPa45 ksi
90 MPa13.1 ksi

Elongation at Break

6%
45%

Reduction in Area

60%
75%

Shear Strength

200 MPa29 ksi
155 MPa22.5 ksi

Fatigue Strength (Endurance Limit)

115 MPa16.7 ksi
80 MPa11.6 ksi

Hardness, Brinell

95 HB
45 HB

Hardness, Vickers

110 HV
55 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Hardness, Rockwell B 50 HRB

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

388 W/m·K224 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

230°C446 °F
350°C662 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100 % IACS
101 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.677 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
20 / 100

Weldability

65 / 100
70 / 100

Formability (cold)

30 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10400

C10400-H04 vs C10400-M20 — frequently asked

Is C10400-H04 stronger than C10400-M20?

Yes. C10400-H04 has a typical yield strength of 310 MPa (45 ksi) against 90 MPa (13.1 ksi) for C10400-M20 — about 3.4 times as much. Tensile strength is 345 MPa (50 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, H04 or M20?

H04 is the default C10400 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C10400-H04 or C10400-M20?

C10400-H04, by a small margin. Both rate poor for machinability — 30/100 against 20/100 for C10400-M20; for welding the order is C10400-M20 first (very good, 70/100) then C10400-H04 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10400-H04 and C10400-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.