FabDigitFabDigit

Copper Alloy C10400-H02 vs C10400-M20

Copper Alloy · C10400 temper comparison

C10400-H02 and C10400-M20 are two conditions of the same copper alloy grade, C10400: H02 (half hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C10400-H02 is the stronger of the two: yield strength 250 MPa (36.3 ksi) against 90 MPa (13.1 ksi) for C10400-M20, about 178% more; tensile strength follows at 290 MPa (42.1 ksi) vs 235 MPa (34.1 ksi). In exchange, C10400-M20 is the more ductile: elongation 45% versus 14% for C10400-H02, and C10400-H02 is harder (82 HB vs 45 HB). C10400-M20 runs hotter in service (350°C vs 240°C continuous).

C10400-H02Choose it when strength drives the design.

C10400-M20Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C10400-H02 vs C10400-M20: properties

C10400-H02C10400-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

290 MPa42.1 ksi
235 MPa34.1 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
90 MPa13.1 ksi

Elongation at Break

14%
45%

Reduction in Area

65%
75%

Shear Strength

185 MPa26.8 ksi
155 MPa22.5 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
80 MPa11.6 ksi

Hardness, Brinell

82 HB
45 HB

Hardness, Rockwell B

40 HRB
50 HRB

Hardness, Vickers

95 HV
55 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

389 W/m·K225 BTU/hr·ft·°F
391 W/m·K226 BTU/hr·ft·°F

Max Service Temperature (continuous)

240°C464 °F
350°C662 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

100 % IACS
101 % IACS

Electrical Resistivity

1.72×10⁻⁸ Ω·m0.677 µΩ·in
1.71×10⁻⁸ Ω·m0.672 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
20 / 100

Weldability

65 / 100
70 / 100

Formability (cold)

55 / 100
95 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Castability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10400

C10400-H02 vs C10400-M20 — frequently asked

Is C10400-H02 stronger than C10400-M20?

Yes. C10400-H02 has a typical yield strength of 250 MPa (36.3 ksi) against 90 MPa (13.1 ksi) for C10400-M20 — about 178% more. Tensile strength is 290 MPa (42.1 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, H02 or M20?

H04 is the default C10400 condition in the FabDigit quote flow (neither H02 nor M20). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C10400-H02 or C10400-M20?

C10400-H02, by a small margin. Both rate poor for machinability — 28/100 against 20/100 for C10400-M20; for welding the order is C10400-M20 first (very good, 70/100) then C10400-H02 (good, 65/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10400-H02 and C10400-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.