C10300-H01 and C10300-H02 are two conditions of the same copper alloy grade, C10300: H01 (quarter hard) versus H02 (half hard). The chemistry is identical, so every difference below comes from the condition. C10300-H02 is the stronger of the two: yield strength 245 MPa (35.5 ksi) against 205 MPa (29.7 ksi) for C10300-H01, about 20% more; tensile strength follows at 280 MPa (40.6 ksi) vs 262 MPa (38 ksi). In exchange, C10300-H01 is the more ductile: elongation 25% versus 14% for C10300-H02, and C10300-H02 is harder (78 HB vs 68 HB).

C10300-H01Choose it when the part is bent, formed or impact-loaded.

C10300-H02Choose it when strength drives the design.

C10300-H01 vs C10300-H02: properties

C10300-H01C10300-H02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

262 MPa38 ksi
280 MPa40.6 ksi

Yield Strength (0.2% offset)

205 MPa29.7 ksi
245 MPa35.5 ksi

Elongation at Break

25%
14%

Reduction in Area

75%
62%

Shear Strength

180 MPa26.1 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
105 MPa15.2 ksi

Hardness, Brinell

68 HB
78 HB

Hardness, Vickers

80 HV
88 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Charpy V-Notch Impact (RT) 70 J51.6 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,083°C1,981 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

389 W/m·K225 BTU/hr·ft·°F
388 W/m·K224 BTU/hr·ft·°F

Max Service Temperature (continuous)

170°C338 °F
160°C320 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 100 % IACS · Electrical Resistivity 1.71×10⁻⁸ Ω·m0.673 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

25%
28%

Weldability

85 / 100
80 / 100

Formability (cold)

78 / 100
60 / 100

Same in both: Machinability 22 / 100 · Castability 45 / 100 · Brazeability / Solderability 95 / 100 · Polishability 80 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC10300

C10300-H01 vs C10300-H02 — frequently asked

Is C10300-H02 stronger than C10300-H01?

Yes. C10300-H02 has a typical yield strength of 245 MPa (35.5 ksi) against 205 MPa (29.7 ksi) for C10300-H01 — about 20% more. Tensile strength is 280 MPa (40.6 ksi) vs 262 MPa (38 ksi).

Which condition does FabDigit quote by default, H01 or H02?

O60 is the default C10300 condition in the FabDigit quote flow (neither H01 nor H02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, C10300-H01 or C10300-H02?

C10300-H01. Its weldability rates excellent (85/100) against very good (80/100) for C10300-H02.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10300-H01 and C10300-H02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.