Phynox-A and Phynox CW+A are two conditions of the same cobalt-chrome alloy grade, Phynox: A (solution annealed) versus CW+A (cold worked and age hardened). The chemistry is identical, so every difference below comes from the condition. Phynox CW+A is the stronger of the two: yield strength 1,850 MPa (268 ksi) against 450 MPa (65.3 ksi) for Phynox-A, about 4.1 times as much; tensile strength follows at 2,050 MPa (297 ksi) vs 950 MPa (138 ksi). In exchange, Phynox-A is the more ductile: elongation 55% versus 3% for Phynox CW+A, and Phynox CW+A is harder (57 HRC vs 26 HRC). Phynox CW+A is stiffer (220 GPa vs 200 GPa) and Phynox-A runs hotter in service (450°C vs 400°C continuous). On the shop floor, Phynox-A welds better (fair vs poor).
Phynox-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
Phynox CW+AChoose it when strength drives the design.
Phynox-A vs Phynox CW+A: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all cobalt-chrome alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all cobalt-chrome alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Shear Strength
Fatigue Strength (Endurance Limit)
Hardness, Rockwell C
Hardness, Vickers
Same in both: Shear Modulus 85 GPa12.3 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.29 · Compressive Strength 1,900 MPa276 ksi
Physical
Density and transition temperatures.
Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,440°C2,624 °F · Liquidus Temperature 1,495°C2,723 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.5 µm/m·K7.5 µin/in·°F · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Same in both: Electrical Conductivity 1.7 % IACS · Electrical Resistivity 1.02×10⁻⁶ Ω·m40.2 µΩ·in
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 85 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Brazeability / Solderability 45 / 100 · Polishability 85 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 130 MJ/kg55,890 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Typical Recycled Content 20%
Strength versus weight
Yield strength against density for every cobalt-chrome alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
Phynox-A vs Phynox CW+A — frequently asked
Is Phynox CW+A stronger than Phynox-A?
Yes. Phynox CW+A has a typical yield strength of 1,850 MPa (268 ksi) against 450 MPa (65.3 ksi) for Phynox-A — about 4.1 times as much. Tensile strength is 2,050 MPa (297 ksi) vs 950 MPa (138 ksi).
Which condition does FabDigit quote by default, A or CW+A?
CW+A is the default Phynox condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, Phynox-A or Phynox CW+A?
Phynox-A. Its machinability rates poor (18/100) against not recommended (10/100) for Phynox CW+A; for welding the order is Phynox-A first (fair, 50/100) then Phynox CW+A (poor, 30/100).