Phynox-A and Phynox CW-1/2H are two conditions of the same cobalt-chrome alloy grade, Phynox: A (solution annealed) versus CW-1/2H (1/2 Hard). The chemistry is identical, so every difference below comes from the condition. Phynox CW-1/2H is the stronger of the two: yield strength 1,250 MPa (181 ksi) against 450 MPa (65.3 ksi) for Phynox-A, about 178% more; tensile strength follows at 1,450 MPa (210 ksi) vs 950 MPa (138 ksi). In exchange, Phynox-A is the more ductile: elongation 55% versus 10% for Phynox CW-1/2H, and Phynox CW-1/2H is harder (45 HRC vs 26 HRC). Phynox-A runs hotter in service (450°C vs 400°C continuous). On the shop floor, Phynox-A welds better (50 vs 40 out of 100).

Phynox-AChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Phynox CW-1/2HChoose it when strength drives the design.

Phynox-A vs Phynox CW-1/2H: properties

Phynox-APhynox CW-1/2H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

200 GPa29 Msi
210 GPa30.5 Msi

Tensile Strength (Ultimate)

950 MPa138 ksi
1,450 MPa210 ksi

Yield Strength (0.2% offset)

450 MPa65.3 ksi
1,250 MPa181 ksi

Elongation at Break

55%
10%

Compressive Strength

1,900 MPa276 ksi
1,300 MPa189 ksi

Shear Strength

600 MPa87 ksi
870 MPa126 ksi

Fatigue Strength (Endurance Limit)

400 MPa58 ksi
600 MPa87 ksi

Hardness, Rockwell C

26 HRC
45 HRC

Hardness, Vickers

270 HV
450 HV

Same in both: Shear Modulus 85 GPa12.3 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.29

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,440°C2,624 °F · Liquidus Temperature 1,495°C2,723 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

450°C842 °F
400°C752 °F

Same in both: Thermal Conductivity 12.6 W/m·K7.3 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 13.5 µm/m·K7.5 µin/in·°F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

1.7 % IACS
1.8 % IACS

Electrical Resistivity

1.02×10⁻⁶ Ω·m40.2 µΩ·in
9.8×10⁻⁷ Ω·m38.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

18 / 100
14 / 100

Machinability Rating (AISI 1212 = 100 %)

14%
12%

Weldability

50 / 100
40 / 100

Formability (cold)

60 / 100
35 / 100

Same in both: Brazeability / Solderability 45 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 130 MJ/kg55,890 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every cobalt-chrome alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

5007001,0001,5002,0008.28.48.68.89Density (g/cm³)Yield strength (MPa) — log scalePhynox

Phynox-A vs Phynox CW-1/2H — frequently asked

Is Phynox CW-1/2H stronger than Phynox-A?

Yes. Phynox CW-1/2H has a typical yield strength of 1,250 MPa (181 ksi) against 450 MPa (65.3 ksi) for Phynox-A — about 178% more. Tensile strength is 1,450 MPa (210 ksi) vs 950 MPa (138 ksi).

Which condition does FabDigit quote by default, A or CW-1/2H?

CW+A is the default Phynox condition in the FabDigit quote flow (neither A nor CW-1/2H). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Phynox-A or Phynox CW-1/2H?

Phynox-A. Its weldability rates fair (50/100) against fair (40/100) for Phynox CW-1/2H.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Phynox-A and Phynox CW-1/2H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.