FabDigitFabDigit

C-210 vs Cordierite

Ceramic · grade comparison

C-210 and Cordierite are both ceramic grades. C-210 is the stronger of the two: tensile strength 70 MPa (10.2 ksi) against 25 MPa (3.63 ksi) for Cordierite, about 180% more. Cordierite is lighter (2.3 g/cm³ vs 3.6 g/cm³ for C-210) and C-210 is stiffer (150 GPa vs 70 GPa). On the shop floor, Cordierite machines more easily (poor vs not recommended) and C-210 sits in a lower cost tier (premium, $$$) than Cordierite (high, $$$$).

C-210Choose it when strength drives the design, or when cost is the deciding factor.

CordieriteChoose it when weight is the constraint, or when the part sees heat.

C-210 vs Cordierite: properties

C-210Cordierite

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

150 GPa21.8 Msi
70 GPa10.2 Msi

Shear Modulus

60 GPa8.7 Msi
28 GPa4.1 Msi

Bulk Modulus

100 GPa14.5 Msi
47 GPa6.8 Msi

Tensile Strength (Ultimate)

70 MPa10.2 ksi
25 MPa3.6 ksi

Compressive Strength

700 MPa102 ksi
350 MPa50.8 ksi

Flexural Strength

150 MPa21.8 ksi
70 MPa10.2 ksi

Fracture Toughness (K_IC)

2 MPa·√m1.8 ksi·√in
1.5 MPa·√m1.4 ksi·√in

Hardness, Mohs

7.5
7

Same in both: Poisson's Ratio 0.25 · Hardness, Vickers 700 HV

Physical

Density and transition temperatures.

Density

3.6 g/cm³0.13 lb/in³
2.3 g/cm³0.08 lb/in³

Porosity

0.2%
8%

Melting Point (Solidus)

—
1,465°C2,669 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

3.5 W/m·K2 BTU/hr·ft·°F
2.5 W/m·K1.4 BTU/hr·ft·°F

Specific Heat Capacity

750 J/kg·K0.18 BTU/lb·°F
800 J/kg·K0.19 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

4.5 µm/m·K2.5 µin/in·°F
2 µm/m·K1.1 µin/in·°F

Max Service Temperature (continuous)

1,000°C1,832 °F
1,250°C2,282 °F

Min Service Temperature

-60°C-76 °F
-200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1×10¹² Ω·m3.94×10¹⁹ µΩ·in
1×10¹¹ Ω·m3.94×10¹⁸ µΩ·in

Dielectric Strength

20 kV/mm508 V/mil
10 kV/mm254 V/mil

Dielectric Constant (1 MHz)

9
5

Dissipation Factor (1 MHz)

0.0015
0.004

Volume Resistivity

1×10¹⁴ Ω·cm
1×10¹³ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

85 / 100
70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

5 / 100
20 / 100

Polishability

70 / 100
35 / 100

Sintering / Firing Temperature

1,300°C2,372 °F
1,350°C2,462 °F

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

25 MJ/kg10,748 BTU/lb
30 MJ/kg12,898 BTU/lb

Embodied Carbon (primary production)

1.8 kg CO₂/kg
2.2 kg CO₂/kg

Embodied Water

25 L/kg3 gal/lb
20 L/kg2.4 gal/lb

Same in both: Typical Recycled Content 5%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

19 kN·m/kg
11 kN·m/kg

Specific Stiffness (E / density)

41.7 MN·m/kg
30.4 MN·m/kg

Thermal Diffusivity

1.3 mm²/s
1.4 mm²/s

Same in both: Thermal Shock Resistance Index 0

Strength versus weight

Yield strength against density for every ceramic grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,000234567Density (g/cm³)Yield strength (MPa) — log scaleCordierite

Manufacturing and finishing

CapabilityC-210Cordierite
Default condition——
Relative cost$$$ Premium$$$$ High
Min. machined wall——
Best machined surface——

C-210 vs Cordierite — frequently asked

Is C-210 stronger than Cordierite?

Yes. C-210 has a typical tensile strength of 70 MPa (10.2 ksi) against 25 MPa (3.63 ksi) for Cordierite — about 180% more.

Which is cheaper, C-210 or Cordierite?

C-210 is the lower-cost material: it sits in the premium tier ($$$) while Cordierite is high ($$$$). Part price depends far more on geometry, tolerance and quantity than on raw stock — upload a CAD file for a live quote.

Which is easier to machine, C-210 or Cordierite?

Cordierite. Its machinability rates poor (20/100) against not recommended (5/100) for C-210.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C-210 and Cordierite side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.