FabDigitFabDigit

Aluminum Scalmalloy As Printed vs Scalmalloy-T6

Aluminum · Scalmalloy temper comparison

Scalmalloy As Printed and Scalmalloy-T6 are two conditions of the same aluminum grade, Scalmalloy: As Printed (as built (as printed)) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. Scalmalloy-T6 is the stronger of the two: yield strength 480 MPa (69.6 ksi) against 285 MPa (41.3 ksi) for Scalmalloy As Printed, about 68% more; tensile strength follows at 520 MPa (75.4 ksi) vs 400 MPa (58 ksi). Scalmalloy-T6 is harder — 145 HB against 100 HB for Scalmalloy As Printed — which matters for wear surfaces and threads. Scalmalloy-T6 runs hotter in service (150°C vs 120°C continuous) and Scalmalloy-T6 conducts electricity better (30 % IACS vs 26 % IACS).

Scalmalloy-T6Choose it when strength drives the design, or when surface hardness matters.

Scalmalloy As Printed vs Scalmalloy-T6: properties

Scalmalloy As PrintedScalmalloy-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
520 MPa75.4 ksi

Yield Strength (0.2% offset)

285 MPa41.3 ksi
480 MPa69.6 ksi

Elongation at Break

14%
13%

Compressive Strength

300 MPa43.5 ksi
490 MPa71.1 ksi

Shear Strength

240 MPa34.8 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

110 MPa16 ksi
175 MPa25.4 ksi

Fracture Toughness (K_IC)

30 MPa·√m27.3 ksi·√in
32 MPa·√m29.1 ksi·√in

Hardness, Brinell

100 HB
145 HB

Hardness, Vickers

105 HV
152 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 68 GPa9.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 574°C1,065 °F · Liquidus Temperature 638°C1,180 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
120 W/m·K69.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.5 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

26 % IACS
30 % IACS

Electrical Resistivity

6.6×10⁻⁸ Ω·m2.6 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 40% · Weldability 60 / 100 · Castability 25 / 100 · Brazeability / Solderability 25 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 350 MJ/kg150,473 BTU/lb · Embodied Carbon (primary production) 26 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 5%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleScalmalloy

Scalmalloy As Printed vs Scalmalloy-T6 — frequently asked

Is Scalmalloy-T6 stronger than Scalmalloy As Printed?

Yes. Scalmalloy-T6 has a typical yield strength of 480 MPa (69.6 ksi) against 285 MPa (41.3 ksi) for Scalmalloy As Printed — about 68% more. Tensile strength is 520 MPa (75.4 ksi) vs 400 MPa (58 ksi).

Which condition does FabDigit quote by default, As Printed or T6?

As Printed is the default Scalmalloy condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, Scalmalloy As Printed or Scalmalloy-T6?

Scalmalloy-T6, by a small margin. Both rate good for machinability — 62/100 against 55/100 for Scalmalloy As Printed.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Scalmalloy As Printed and Scalmalloy-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.