FabDigitFabDigit

Aluminum ER1188-F vs ER1188-O

Aluminum · ER1188 temper comparison

ER1188-F and ER1188-O are two conditions of the same aluminum grade, ER1188: F (as fabricated) versus O (annealed). The chemistry is identical, so every difference below comes from the condition. ER1188-F is the stronger of the two: yield strength 50 MPa (7.25 ksi) against 22 MPa (3.19 ksi) for ER1188-O, about 127% more; tensile strength follows at 85 MPa (12.3 ksi) vs 60 MPa (8.7 ksi). In exchange, ER1188-O is the more ductile: elongation 45% versus 20% for ER1188-F, and ER1188-F is harder (24 HB vs 18 HB). ER1188-O runs hotter in service (150°C vs 120°C continuous).

ER1188-FChoose it when strength drives the design.

ER1188-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

ER1188-F vs ER1188-O: properties

ER1188-FER1188-O

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

85 MPa12.3 ksi
60 MPa8.7 ksi

Yield Strength (0.2% offset)

50 MPa7.3 ksi
22 MPa3.2 ksi

Elongation at Break

20%
45%

Shear Strength

55 MPa8 ksi
40 MPa5.8 ksi

Fatigue Strength (Endurance Limit)

28 MPa4.1 ksi
20 MPa2.9 ksi

Hardness, Brinell

24 HB
18 HB

Same in both: Elastic (Young's) Modulus 68 GPa9.9 Msi · Shear Modulus 25.5 GPa3.7 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 657°C1,215 °F · Liquidus Temperature 660°C1,220 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

233 W/m·K135 BTU/hr·ft·°F
235 W/m·K136 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

64 % IACS
64.5 % IACS

Electrical Resistivity

2.69×10⁻⁸ Ω·m1.06 µΩ·in
2.67×10⁻⁸ Ω·m1.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

78 / 100
80 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.85 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

25 / 100
22 / 100

Machinability Rating (AISI 1212 = 100 %)

30%
25%

Formability (cold)

85 / 100
98 / 100

Same in both: Weldability 96 / 100 · Castability 45 / 100 · Brazeability / Solderability 85 / 100 · Polishability 92 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 240 MJ/kg103,182 BTU/lb · Embodied Carbon (primary production) 16 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleER1188

ER1188-F vs ER1188-O — frequently asked

Is ER1188-F stronger than ER1188-O?

Yes. ER1188-F has a typical yield strength of 50 MPa (7.25 ksi) against 22 MPa (3.19 ksi) for ER1188-O — about 127% more. Tensile strength is 85 MPa (12.3 ksi) vs 60 MPa (8.7 ksi).

Which condition does FabDigit quote by default, F or O?

AW is the default ER1188 condition in the FabDigit quote flow (neither F nor O). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ER1188-F over ER1188-O?

Pick ER1188-F when strength drives the design. Pick ER1188-O when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ER1188-F and ER1188-O side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.