FabDigitFabDigit

Aluminum EN AC-71100-T1 vs EN AC-71100-T5

Aluminum · EN AC-71100 temper comparison

EN AC-71100-T1 and EN AC-71100-T5 are two conditions of the same aluminum grade, EN AC-71100: T1 (cooled from hot working and naturally aged) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. Both yield at about 205 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cooled from hot working and naturally aged versus cooled from hot working and artificially aged). EN AC-71100-T1 is the more ductile: elongation 1.5% versus 1.2% for EN AC-71100-T5, and EN AC-71100-T5 is harder (95 HB vs 90 HB).

EN AC-71100-T1Choose it when the part is bent, formed or impact-loaded.

EN AC-71100-T1 vs EN AC-71100-T5: properties

EN AC-71100-T1EN AC-71100-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

270 MPa39.2 ksi
275 MPa39.9 ksi

Yield Strength (0.2% offset)

205 MPa29.7 ksi
215 MPa31.2 ksi

Elongation at Break

1.5%
1.2%

Compressive Strength

215 MPa31.2 ksi
225 MPa32.6 ksi

Shear Strength

170 MPa24.7 ksi
175 MPa25.4 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
14 MPa·√m12.7 ksi·√in

Charpy V-Notch Impact (RT)

2 J1.5 ft·lbf
2 J1.3 ft·lbf

Hardness, Brinell

90 HB
95 HB

Hardness, Rockwell B

52 HRB
56 HRB

Hardness, Vickers

95 HV
100 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Fatigue Strength (Endurance Limit) 85 MPa12.3 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.9 g/cm³0.1 lb/in³ · Melting Point (Solidus) 550°C1,022 °F · Liquidus Temperature 600°C1,112 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

110 W/m·K63.6 BTU/hr·ft·°F
108 W/m·K62.4 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
160°C320 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 400 J/g172 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
26 % IACS

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
6.6×10⁻⁸ Ω·m2.6 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V · Corrosion Resistance 40 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
73 / 100

Machinability Rating (AISI 1212 = 100 %)

130%
132%

Formability (cold)

5 / 100
4 / 100

Same in both: Weldability 20 / 100 · Castability 75 / 100 · Brazeability / Solderability 20 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-71100

EN AC-71100-T1 vs EN AC-71100-T5 — frequently asked

What is the difference between EN AC-71100-T1 and EN AC-71100-T5?

EN AC-71100-T1 and EN AC-71100-T5 are two conditions of the same aluminum grade, EN AC-71100: T1 (cooled from hot working and naturally aged) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. Both yield at about 205 MPa — the mechanical properties are the same, and the difference is in how the stock is processed and what it is certified to (cooled from hot working and naturally aged versus cooled from hot working and artificially aged).

Which condition does FabDigit quote by default, T1 or T5?

T1 is the default EN AC-71100 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-71100-T1 over EN AC-71100-T5?

Pick EN AC-71100-T1 when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-71100-T1 and EN AC-71100-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.